background image

Activation of an immediate alarm

The  control  panel  has  3  alarms  which  can  be  activated  immediately  from
the  Control  Keypad  and  which  correspond  to  three  methods  of  activating
the alarm itself: 

 - activation of siren and communicator;

 - activation of siren only;

 - activation of communicator only.

Operating from Keypad

superkey

 

The  activation  of  the  alarms  takes  place  by  pressing  the  relative  key  for
about 3 seconds. The acceptance of the operation will be confirmed by the
special acoustic signal.

Temporary partitioning of the groups

In some cases it may be necessary, when the system is armed, to exclude
a group of zones temporarily for to reinclude it later (patrol round, service
personnel access, etc.). This operation is practicable both with the Keypad
as well as from the key reader using slightly different methods.

Operating from the remote control key readers

You must insert a valid key in one of the key readers and press the button
without releasing it: the system will not change its condition but the leds re-
lating to the partitioning groups will begin to scan the various possible con-
figurations, at this point release the button when the configuration desired
appears. This operation is possible both with a master key as well as with
a secondary key. The reinclusion of the group will take place:

carrying out the same operation with the key;

disarming the system.

+

This operation is realizable following the same methods both from the key
readers on the panel as well as from the remote control key readers.

+

For the temporary partitioning carried out with the electronic key, the auto-
matic reinclusion 

is not envisaged

 after the patrol time.

+

If you must supply the service personnel with a key for carrying out this op-
eration it is advisable to programme a secondary key so that it is impossi-
ble to disarm the system.

OPERATIONS

19

Содержание NormaOtto Series

Страница 1: ......

Страница 2: ...ject to change without notice and does not represent any obligation behalf of BENTEL srl via Florida Z I Valtesino 63013 GROTTAMMARE AP ITALY USER MANUAL Alarm control panel NormaQuattro and NormaOtto ISTNORMA8USO UK 0 2 281100 V4 2 BUU ...

Страница 3: ...al arming of the system 12 Partial arming of the system 13 Quick arm of the system 14 Disarming the system 14 Forced disarming 15 Entering into the service mode 15 Resetting of the alarm memories 16 Blocking of the alarm in course 16 Extensive visualization 17 Individual exclusion of the zones 18 Activation of an immediate alarm 19 Temporary partitioning of the groups 19 User codes programming 21 ...

Страница 4: ...Figure 1 Control panel system components 4 Alarm control panel NORMA4 and NORMA8 ...

Страница 5: ...is also possible to connect a remote Control Keypad by which you can control all the functions of the system In particular it is possible to arm and disarm the system by means of entering a secret user s code of four or five figures in this way the utilization of the keys is not necessary Your installer will be able to show you the special characteristics of the particular plant whilst in this han...

Страница 6: ... that the control panel ignores that zone therefore violating it will not set off the alarm PARTITIONING Partitioning the system means excluding a group of zones In this way the system is armed but a part remains inactive so that you can stay in a restricted zone inside the protected building PARTITIONING GROUPS A group of zones where partitioning is carried out ANTI SABOTAGE ZONE A particular zon...

Страница 7: ...ry zone E2 Main indicates the lack of voltage the control panel will be supplied by the internal battery If this condition continues for long it will result in the running down of the same battery E3 Battery if the light is on it indicates that the battery is run down or that there is a fault in the battery charging circuit if flashing it refers to the battery of the siren E4 Bus indicates a fault...

Страница 8: ...ver the buzzer indicates with various sounds the elapsing of the exit time the pre alarm condition and the alarm condition The electronic key By means of the electronic key operated by NormaQuattro and Nor maOtto it is possible to carry out in a quick and simple manner the main operations on the system There are two different levels of keys the master key main key with which you can carry out all ...

Страница 9: ...tions and supplies the responses to the keys pressed as with on the control panel User s codes The users have at their disposal 5 different codes each of which is en abled for specific functions In this way each of the system s users by means of his personal code is able to carry out only the operations re served for him All the codes may be composed of four or five figures and the operations on t...

Страница 10: ...ATROL ON activated to control the temporary exclusion of a group of zones for patrol rounds The re inclusion will take place in this case automatically after the predetermined patrol time The standard factory programming of the user s codes is the following USER MAIN 1 1 1 1 1 USER 2 2 2 2 2 PANIC 3 3 3 3 3 GROUP A 4 4 4 4 4 GROUP B 5 5 5 5 5 Superkeys Some operations are not activated by user cod...

Страница 11: ...ES NO Resetting alarm memories YES NO YES Block of current alarm YES YES YES Extensive visualization YES NO YES Individual exclusion of zones YES NO YES Immediate activating of an alarm NO NO YES Temporary partitioning of groups YES K YES YES Programming of user codes NO NO YES All the operations realizable from the panel with the electronic key which don t anticipate the use of the buttons are re...

Страница 12: ...master key into the key reader press the button and make sure that the red led lights up At this point the moment in which the key is extracted is when the actual arming of the system will take place Before carrying out the arming of the system make sure that the red led of the key reader is not flashing In fact a flashing red led indicates that at that moment there is at least one zone open armin...

Страница 13: ...roups will begin in dicated by the lighting up of the group leds yellow group A green group B when the configuration desired appears release the button and extract the key The lit up led means that the group is excluded Operating from a remote control key reader The procedure is the same as for the Electronic key in the previous para graph Operating from the Keypad The partial arming of the system...

Страница 14: ... red led on the key readers Operating from the panel OR Mechanical key When the system is armed in order to disarm it you must insert the me chanical key turn it to the right and quickly release it Electronic key When the system is armed in order to disarm it you must insert a master key in the key reader and press the button In this way the arming red led will be extinguished By turning the key y...

Страница 15: ...e on the front panel The service mode is also useful for blocking an alarm in course because during the service mode all the alarms are disarmed Operating from the panel OR Mechanical key Turn the key to the right and hold it in position for about 3 seconds until you can hear an acoustic signal and the Service led lights up You can exit from the service mode repeating the same operation or after n...

Страница 16: ... panel With the control panel disarmed put it into the service mode and press the button RESET The alarm memory indication on the zones will be can celled Operating from the Keypad Type in the USER MAIN code followed by the function key RES Blocking of the alarm in course When an alarm condition takes place the connected alarm devices will be activated such as the siren and the telephone warning d...

Страница 17: ...aulty conditions are responsible and sub sequently call technical assistance in order to eliminate them If you forget to complete the extensive visualization phase then the control panel will continue to operate as normal except for the fact that the zone and exclusion zone leds will have the meaning indicated above All the functions of the control panel alarms etc will be completely operational O...

Страница 18: ...ation will be indicated by the error signal Operating from the panel The exclusion of the zones is carried out by means of special exclusion keys only when the control panel is disarmed and in the service mode Operating from the Keypad The exclusion and the reinclusion of zones is possible only when the sys tem is disarmed by typing the USER MAIN code followed by EXC Doing this gives you access to...

Страница 19: ...ting from the remote control key readers You must insert a valid key in one of the key readers and press the button without releasing it the system will not change its condition but the leds re lating to the partitioning groups will begin to scan the various possible con figurations at this point release the button when the configuration desired appears This operation is possible both with a maste...

Страница 20: ...ctivated Patrol active disarming the system It must be observed that the exclusion of groups overlaps to that of each single zone therefore if before the exclusion of groups a zone has already been excluded then on the reinclusion of the group it will remain the same The exclusions will however always be clearly indicated on the panel and on the Control Keypads by means of the exclusion leds and o...

Страница 21: ...hoices will be cancelled since they are reserved to the installer and one led will light up on the right side At this point the programming Mask relative to codes programming is inserted the lighted led must coincide to the one indicated on the mask If during this phase ENTER is pressed one returns to the operative phase of the Control Panel the yellow light relative to the programming phase will ...

Страница 22: ...t codes of 5 digits with 0 as the last number are not possible Exit from programming phase To return to the normal operative phase it is necessary to key in ENTER 1 2 or 3 times according to wether you are in phase a b or c and in any case until the yellow led that indicates the programming phase goes off When the codes are being programmed it is advisable to write them down by using the table her...

Страница 23: ...________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ FOR ASSISTANCE ...

Страница 24: ...m disarming USER MAIN USER Forced disarming PANIC Alarm memory reset USER MAIN Stop an alarm in progress USER MAIN USER MAIN Extensive visualization Super key Exclusion of single zones USER MAIN Communicator immediate alarm activation Super key Super key Super key Temporary division GROUP A GROUP B User codes programming USER MAIN ISTNORMA8USO UK 0 2 281100 ...

Отзывы: