Activation of an immediate alarm
The control panel has 3 alarms which can be activated immediately from
the Control Keypad and which correspond to three methods of activating
the alarm itself:
- activation of siren and communicator;
- activation of siren only;
- activation of communicator only.
Operating from Keypad
superkey
The activation of the alarms takes place by pressing the relative key for
about 3 seconds. The acceptance of the operation will be confirmed by the
special acoustic signal.
Temporary partitioning of the groups
In some cases it may be necessary, when the system is armed, to exclude
a group of zones temporarily for to reinclude it later (patrol round, service
personnel access, etc.). This operation is practicable both with the Keypad
as well as from the key reader using slightly different methods.
Operating from the remote control key readers
You must insert a valid key in one of the key readers and press the button
without releasing it: the system will not change its condition but the leds re-
lating to the partitioning groups will begin to scan the various possible con-
figurations, at this point release the button when the configuration desired
appears. This operation is possible both with a master key as well as with
a secondary key. The reinclusion of the group will take place:
carrying out the same operation with the key;
disarming the system.
+
This operation is realizable following the same methods both from the key
readers on the panel as well as from the remote control key readers.
+
For the temporary partitioning carried out with the electronic key, the auto-
matic reinclusion
is not envisaged
after the patrol time.
+
If you must supply the service personnel with a key for carrying out this op-
eration it is advisable to programme a secondary key so that it is impossi-
ble to disarm the system.