COMPLIANCE NOTICES 

 
The Benson RS/UHA2 range of warm air heaters detailed herewith are manufactured for Benson Heating within the 
parameters of ISO 9002. 
 
The Benson RS/UHA2 Range has been independently tested and assessed, and has been found to meet the Essential 
Requirement of the following European Directives: 

 

Gas appliance Directive (90/396/EEC) 
Machinery Directive (89/392/EEC) 91368/EEC 93/44/EEC 93/65/EEC 
Low Voltage Directive (73/23/EEC  
Electromagnetic Compatibility Directive (98/336/EEC and 91/31/EEC) 
Product Liability Directive (65/374/EEC) 

 

The manufacturer has taken reasonable and practical steps to ensure that Benson RS/UHA2 Range of Heaters are safe 
and without risk when properly used. These heaters should therefore only be used in the manner and purpose for which 
they were intended, and in accordance with the recommendations detailed herewith. 
The heaters have been designed, manufactured, assembled, inspected, and tested, with safety and quality in mind, there 
are certain basic precautions which the installer and user should be aware of, and they are strongly advised to read the 
appropriate sections of the information pack accompanying the heater, prior to installation or use. 
 
Benson Heating supports all new products being supplied to their customers with a comprehensive information pack; this 
clearly defines mandatory instructions for the safe installation, use, and maintenance, of the appliance(s). 
 
Where proprietary items are incorporated into Benson Heating products, detailed information and instructions are also 
provided as part of the information pack. 
 
It is the responsibility of the installer, owner, user, or hirer, of such products supplied by Benson Heating, to ensure that 
they are familiar with the appropriate information/manuals, supplied by the manufacturer, and that they are suitably 
aware of the purpose of the manuals and the safety instructions. In addition, operators must be suitably trained in the use 
of the appliance so as to ensure its continued safe and efficient use. 
 
Benson Heating has a commitment to continuous improvement, and therefore reserves the right to amend or change the 
specification of the RS/UHA2Heater range subject to agreement from The Notified Body.  
 
Contained within the text of the manual, the words '

Caution

' and '

Warning

' are used to highlight certain points. 

 

Caution

 is used when failure to follow or implement the instruction(s) can lead to premature failure or damage to the 

heater or its component parts. 
 

Warning

 is used when failure to heed or implement the instruction(s) can lead to not only component damage, but also 

to a hazardous situation being created where there is a risk of personal injury. 
 

Notified Body PIN Reference is  

 

RANGE 

 

Type Model Code 

1 RS/UHA2 

50 

3TAIT2C016 

2 RS/UHA2 

80 

3TAIT2C026 

3 RS/UHA2 

105 

3TAIT2C036 

4 RS/UHA2 

140 

3TAIT2C046 

5 RS/UHA2 

200 

3TAIT2C066 

6 RS/UHA2 

260 

3TAIT2C086 

7 RS/UHA2 

325 

3TAIT2C106 

 

 

 
 
 
 
 
 
 
 
 

Содержание RS/UHA2 105

Страница 1: ...ed unit heaters 2 stage TECHNICAL INFORMATION ASSEMBLY INSTRUCTIONS USE AND MAINTENANCE RS UHA 2 BENSON HEATING LUDLOW ROAD KNIGHTON POWYS LD7 1LP MAY 2003 Benson Heating is a divison of Benson Climat...

Страница 2: ...uctions for the safe installation use and maintenance of the appliance s Where proprietary items are incorporated into Benson Heating products detailed information and instructions are also provided a...

Страница 3: ...R THE USER Operation Servicing Heater indication lights Receipt of product Transport Dimension FOR THE INSTALLER Location Wall bracket dimensions Gas connection Flue and combustion options Electrical...

Страница 4: ...cond stage gas valve 2 C Fan capacitor FAN 1 Axial fan 1 FAN 2 Axial fan 2 type 5 F1 F2 Line fuse 6 3 A LF Green working light LL High temperature indication light LB Lockout indication RST Lockout re...

Страница 5: ...II Second stage gas valve 2 C Fan capacitor FAN 1 Axial fan 1 FAN 2 Axial fan 2 FAN 3 Axial fan 3 Type 7 F1 F2 Line fuse LF Green working light LL High temperature indication light LB Lockout indicat...

Страница 6: ...indicating gas type 6 Ensure settings are correct as per the manual and data plate CHANGE INJECTORS To change injectors Unscrew the natural gas injectors and replace them with the correct size inject...

Страница 7: ...en the gas isolating cock switch on the electrical supply set the room thermostat to the desired temperature The heater is now ready for operation GAS VALVE Model SIT 843 two stage The heater must onl...

Страница 8: ...ponents are correct for the installation including storage tank pipes and pressure valves etc Ensure that the pressure regulators are sealed after carrying out the conversion GAS PRESSURE REGULATION T...

Страница 9: ...orrect pressure according to the data plate is achieved Gas valve head pressure setting low fire Propane G31 When setting the gas pressure for propane low fire first stage contact SF should be open Th...

Страница 10: ...orking Check flue pipe and combustion air pipe are clear Faulty differential pressure switch Replace differential pressure switch Poor connection at pressure switch Check air pipe to switch is connect...

Страница 11: ...bar Faulty burner tube Replace the burner tube Faulty ignition transformer Replace ignition transformer Faulty ignition Check the gas type is suitable for the heater Check the inlet gas pressure Check...

Страница 12: ...correct and the air flow over the chamber is sufficient Faulty SND thermostat or control panel Replace SND thermostat or control panel Burner goes out due to the intervention of the TR thermostat and...

Страница 13: ...and the air flow over the chamber is sufficient Faulty thermostat Replace thermostat Faulty fan Check fan capacitor Check fan motor Intervention of thermal overload on fan Check electrical absorption...

Страница 14: ...heater Check the gas pressure Check burner head pressure The fan does not work Defective fan control Change fan control or SND thermostat Faulty fan Check fan capacitor Check the fan motor The heater...

Страница 15: ...B22 Single flue option with condensate tee and roof terminal combustion air from inside the room Type 1 2 3 4...

Страница 16: ...1000 with seal T Terminal with guard 100 U Condensate Tee with drain point V Pipe M M 100 L 200 without seal NOTE IMPORTANT MODEL 1 2 3 4 FLUE SPIGOT 100 female COMBUSTION AIR SPIGOT 100 female INSTA...

Страница 17: ...165 ITEM DESCRIPTION A Pipe M F 100 L 1000 with seal T Terminal with guard 100 U Condensate tee with drain point Z Pipe M F 100 L 250 with seal NOTE IMPORTANT MODEL 5 6 7 FLUE SPIGOT SIZE 100 male COM...

Страница 18: ...RIPTION A Flue pipe M F 100 L 1000 with seal H Bend 90 M F 100 with seal L Vertical co axial roof terminal kit 100 100 U Condensate tee with drain point V pipe M M 100 L 200 without seal NOTE IMPORTAN...

Страница 19: ...with seal N Vertical co axial roof terminal kit 100 150 P Adaptor F F 150 L 200 with seal Q Bend 45 M F 150 with seal R Pipe M F 150 L 140 with seal S Bend 90 F F 100 with seal U Condensate tee with d...

Отзывы: