99
Digital/Relay Outputs (DO1, DO2, RO1, RO2 Config)
I/O 08, 09, 10, 11
I/O: DO1 Config
08 DRV Ready
I/O: DO2 Config
09 At Speed
7 - PARAMETER DESCRIPTION
LCD Display
Range
Parameter Value
Function
Not Assign
Digital output is not used
Drive Run (R2 Default)
Drive is running
Running Fwd
Drive is running in Forward
Running Rev
Drive is running in Reverse
Drv Ready (DO1 Default)
Drive is powered-up and ready
At Speed (D02 Default)
Drive has reached the reference speed
Drv Fault (R1 Default)
Drive is in the faulted state
Drv NotFlt
Drive is not in the faulted state
Kpd in Ctl
The keypad is the control and reference source
Drv in Rem
The drive is in remote control
Jogging
Drive is Jogging
Curr Lvl 1
Value of parameter FUN 26 (Current Level 1) is exceeded
Curr Lvl 2
Value of parameter FUN 27 (Current Level 2) is exceeded
Trq Lvl 1
Value of parameter FUN 28 (Torque Level 1) is exceeded
Trq Lvl 2
Value of parameter FUN 29 (Torque Level 2) is exceeded
Frq Lvl 1
Value of parameter FUN 30 (Frequency Level 1) is exceeded
Frq Lvl 2
Value of parameter FUN 31 (Frequency Level 2) is exceeded
Frq Lvl 3
Value of parameter FUN 32 (Frequency Level 3) is exceeded
Current Lim
Current Limit mode is active
Loss Ref
Loss of 4 to 20mADC follower
SL in Ctrl
Serial Control in control, control bit SLC set
SL Override
Control by Serial Link being overridden
Zero Speed
The drive is in Run mode, but the speed reference is 0Hz. See AFN39 (Sleep Mode)
Frq Low Thr
The drive frequency is below the value set in FUN 33 (Low FreqThr)
PID High
The PID output is above the value in AFN 37 (PID High Alarm)
PID Low
The PID output is below the value in AFN 38 (PID Low Alarm)
Timer 1
Timer 1 output (See FUN 34, 35)
Timer 2
Timer 2 output (See FUN 36, 37)
SEQOUT-00
Drive is in Sequence 00
SEQOUT-01
Drive is in Sequence 01
SEQOUT-10
Drive is in Sequence 10
SEQOUT-11
Drive is in Sequence 11
Arctic Mode
Drive is in Arctic Mode
Description
These parameters configure what actions or states cause the digital outputs (terminal DQ1–DQ2) to
become active.
z
NOTE:
Only Active Low (pull-down) logic is available for the digital outputs.
See also
108.
I/O: R2 Config
11 Drive Run
I/O: R1 Config
10 Drv Fault
Содержание RSi S4 Series
Страница 4: ......
Страница 9: ...1 1 Introduction...
Страница 16: ...8 1 INTRODUCTION NOTES...
Страница 17: ...9 2 Technical Specifications...
Страница 28: ...20 2 TECHNICAL SPECIFICATIONS NOTES...
Страница 29: ...21 3 Installation...
Страница 37: ...29 4 Connections...
Страница 51: ...43 4 CONNECTIONS 4 5 2 S4 Wiring Diagram S4 Series Wiring Diagram...
Страница 56: ...48 4 CONNECTIONS NOTES...
Страница 57: ...49 5 Keypad Operation and Programming...
Страница 70: ...62 NOTES 5 KEYPAD OPERATION AND PROGRAMMING...
Страница 71: ...63 6 Parameter Groups...
Страница 82: ...74 NOTES 6 S4 Parameter Groups...
Страница 83: ...75 7 Parameter Descriptions...
Страница 149: ...141 8 Troubleshooting Maintenance...
Страница 159: ...151 9 Motor Characteristics...
Страница 162: ...154 9 MOTOR CHARACTERISTICS NOTES...
Страница 163: ...155 10 Options...
Страница 165: ...157 11 Appendices...