2. Installation -20
2. Installation
This chapter gives step-by-step instructions about how to install the
switch:
2.1 Operating Environment
As with any electric device, you should place the switch where it
will not be subjected to extreme temperatures, humidity, or
electromagnetic interference. Specifically, the site you select
should meet the following requirements:
- The ambient temperature should be between 32 and 122
degrees Fahrenheit (0 to 50 degrees Celsius).
- The relative humidity should be less than 90 percent,
non-condensing.
- Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards for IEC 801-3, Level 2
(3V/M) field strength.
- Make sure that the switch receives adequate ventilation. Do
not block the ventilation holes on each side of the switch or
the fan exhaust port on the rear of the switch.
- The power outlet should be within 1.8 meters of the switch.