Serial communication control
37
Serial communication control
Under common working condition, the camera could be controlled through RS232/
RS485 interface (VISCA); RS232C serial parameter are as follows:
Baud rate: 2400/4800/9600/115200 bits / sec; Start bit: 1; data bits: 8; Stop bit: 1; Parity:
None.
After power on, the camera first go left, then back to the middle position. Self-test is
finished after the zoom moved to the farthest and then back to the nearest position. If
the camera saved 0 preset before, it will be back to that position after initialization. At
this point, the user can control the camera by the serial commands.
VISCA protocol list
Camera return command
z = camera a 8
Ack/Completion Message
Command packet
Note
ACK
z0 41 FF
Returned when the command is accepted.
Completion
z0 51 FF
Returned when the command has been executed.
Error Messages
Command packet
Note
Syntax Error
z0 60 02 FF
Returned when the command format is different
or when a command with illegal command
parameters is accepted.
Command Not
Executable
z0 61 41 FF
Returned when a command cannot be executed
due to current conditions. For example, when
commands controlling the focus manually are
received during auto focus.
Содержание DVY23
Страница 1: ...DVY23 Full HD Camera User Manual...
Страница 10: ...Installation instructions 10...
Страница 11: ...Installation instructions 11 2 Ceiling mount steps...
Страница 12: ...Installation instructions 12...
Страница 56: ...Product information 56 Dimensions Unit mm...