03/ 2009
BENNING IT 101
D F
H
I
Bild 10:
Gespeicherte Werte der
Isolationsmessung
Fig. 10:
Stored values of the insulation
measurement
Fig. 10:
Valeurs mémorisées de la mesure
d‘isolement
Obr. 10: Uložené hodnoty měření izolace
Εικόνα 10: Αποθηκευμένες τιμές της μέτρησης της
μόνωσης
10. ábra: Tárolt szigetelésmérési értékek
Ill. 10:
Valori salvati di misurazione
dell‘isolamento
Fig. 10:
Opgeslagen waarden van de
isolatiemeting
Rysunek 10:
Zapisane wartości pomiaru izolacji
Imaginea 10:
Valori memorate ale măsurării izolaţiei.
Bild 11:
Gespeicherte Werte der DAR-Messung
Fig. 11:
Stored values of the DAR measurement
Fig. 11:
Valeurs mémorisées de la mesure
«DAR»
Obr. 11: Uložené hodnoty měření DAR
Εικόνα 11: Αποθηκευμένες τιμές της μέτρησης DAR
(ρυθμός διηλεκτρικής απορρόφησης)
11. ábra: Tárolt DAR-mérési érték előhívása
Ill. 11:
Valori salvati di misurazione del DAR
Fig. 11:
Opgeslagen waarden van de DAR-meting
Rysunek 11:
Zapisanych wartości pomiarów DAR
Imaginea 11:
Valori stocate ale măsurării-DAR.
9
Using the Store function
Store/Recall button
�
The screen will be flashing MEM symbol and the number of
stored data twice when the Store/Recall button is pressed.
1. Press once to store the voltage value during voltage test
2. Press once to store the PI/ DAR, insulation or Earth-bond
resistance value when the individual test is completed.
3. The memory is divided into five segments
,
each segments
has 100 maximum data. The method to store the data is first
in /first out when the memory is full.
Table: The stored values of the individual test
segments
Items
Voltage Earth-Bond
resistance
Insulation
resistance
50~1000V
DAR
PI
1
Voltage Resistance Resistance
DAR
value PI value
2
Leakage
current
R30-sec R1-min
3
Test voltage R1-min R10-min
Search the stored value under RECALL mode
NOTE :
Press the Store/Recall button
≧
5 sec to clear the stored data.
The screen will be flashing MEM symbol and “
cLr
” on
reading twice.
Using the Recall function
Press the Store/Recall button
≧
2 sec to enter/exit the RECALL
mode.
If the memory is empty, the meter will display the “nOnE ”
symbol.
10
Read the stored value of insulation test under
RECALL mode
Read the stored value of DAR test under
RECALL mode
Press the PI/DAR button
≧
2 sec to choose the DAR
function, and Press the Store/Recall button
≧
2 sec to enter
the RECALL mode.
10
Read the stored value of insulation test under
RECALL mode
Read the stored value of DAR test under
RECALL mode
Press the PI/DAR button
≧
2 sec to choose the DAR
function, and Press the Store/Recall button
≧
2 sec to enter
the RECALL mode.
Bild 9:
Gespeicherte Messwerte aufrufen
Fig. 9:
Calling stored measured values
Fig. 9:
Appel des valeurs mesurées mémorisées
Obr. 9:
Vyvolání uložených naměřených hodnot
Εικόνα 9: Ανάκληση αποθηκευμένων τιμών
μέτρησης
9. ábra:
Tárolt mérési érték előhívásal
Ill. 9:
Visualizzazione dei valori salvati
Fig. 9:
Opgeslagen meetwaarden opvragen
Rysunek 9: Przywołanie zapisanych wartości
Imaginea 9: Apelarea valorilor măsurate şi stocate
(memorate).