Bennett PULSER Скачать руководство пользователя страница 6

Bennett Pulser Assembly Instruction Manual 

Safety Information 

GENERAL INFORMATION  

Read this manual carefully and read all tags/labels attached to the Pulser Assembly before starting any maintenance and/or service. A 
Pulser that is not properly maintained will not perform properly and will void the Bennett Limited Warranty. 

Before installation, operation, maintenance and/or service ensure that protection against lighting strikes are in accordance with the 
American Petroleum Institute Recommended Practice RP 2003, Protection Against Ignitions Arising out of Static, Lightening, and Stray 
Currents

Service of the Bennett products and all accessories must be performed by a technician who is trained in accordance to all codes, 
standards, and regulations. 

HAZARDOUS LOCATIONS  

For safe operation, ensure that the dispenser is in a classified area as detailed below per NFPA 30, Flammable and Combustible Liquids 
Code
 and NFPA 70, National Electric Code. For further information on the classification of locations for Fuel Dispensers, see NFPA 30, 
Flammable and Combustible Liquids Code.  

When used with the Bennett Electronics, certified to be used in Hazardous location: Class 1 Division 1 Group D area 

CODES AND STANDARDS  

Follow all local, state, and federal requirements for installation of all equipment. 

 

API 2003 – Protection Against Ignitions Arising Out of Stray, Lightning, and Stray Currents 

 

NFPA 30 – Flammable and Combustible Liquids Standard 

 

NFPA 30A – Motor Fuel Dispensing Facilities Standard 

 

NFPA 70 – National Electric Code 

 

International Fire Code – 2018 Edition 

 

Weights & Measures Handbook 44 

UNAUTHORIZED ALTERAT ION OF BENNETT PRODU CTS 

DANGER: 

BEFORE PERFORMING ANY TYPE OF SERVICE TO THE DISPENSERS, BE SURE TO SHUT OFF ALL ELECTRICAL 
SUPPLIES AND SECURE THEM IN THE OFF POSITION. CLOSE ALL VALVES IN INCOMING PIPING. MAINTENANCE 
MUST BE PERFORMED BY TRAINED PERSONAL ONLY. 

Bennett Pump Company products are designed to meet or exceed the standards of Underwriters Laboratories, Inc., Federal 
Communication Commission, and National Institute of Standards and Technology. Compliance with these standards protects the operator 
and the consumer from personal injury and ensure an accurate delivery of product. Any deviation from the use of authorized 
replacement parts or alteration of a designed product configuration may cause personal injury, death or the revocation of one or all of 
the above approvals. 

Bennett Pump Company will not assume responsibility or liability for any consequential injury or damage caused by the unauthorized 
alteration of its products. 

ABBREVIATIONS AND AC RONYMS 

 

 

 

Term 

Description 

AC 

Alternating Current 

API 

America Petroleum Institute 

AHJ 

Authorities Having Jurisdiction 

DC 

Direct Current 

EPA 

Environmental Protection Agency 

Hz 

Hertz 

NEC 

National Electrical Code 

NFPA 

National Fire Protection Agency 

NREL 

National Renewable Energy Laboratory 

OEM 

Original Equipment Manufacturer 

OIML 

International Organization of Legal Metrology 

PEI 

Petroleum Equipment Institute 

UL 

Underwriters Laboratories, Inc. 

VAC 

Voltage Alternating Current 

VDC 

Voltage Direct Current 

Содержание PULSER

Страница 1: ...2020 Only Trained Personnel May Work on This Equipment READ THIS MANUAL This manual has important information for safe installation and operation of this equipment Read and understand this manual befo...

Страница 2: ...outside USA 231 798 1310 Extension 287 or 269 Customer Service USA 231 719 6050 Facsimile USA 231 799 6202 Email sales bennettpump com or salesintl bennettpump com Website www bennettpump com For new...

Страница 3: ...f Bennett Products 4 Abbreviations and Acronyms 4 SECTION 2 PRODUCT INTRODUCTION 5 Features 5 Specifications 5 Pulser Assembly 6 SECTION 3 INSTALLATION INSTRUCTIONS 9 How to Remove Pulser Cover 9 How...

Страница 4: ...Bennett Pulser Assembly Instruction Manual Table of Contents ii Page Intentionally Left Blank...

Страница 5: ...submerged pump before working on it Maintenance repairs must be done by authorized personnel only Warranty work may only be performed by Bennett certified technicians To prevent electric shock keep th...

Страница 6: ...NFPA 30A Motor Fuel Dispensing Facilities Standard NFPA 70 National Electric Code International Fire Code 2018 Edition Weights Measures Handbook 44 UNAUTHORIZED ALTERATION OF BENNETT PRODUCTS DANGER...

Страница 7: ...Barrier Boards are covered by a plastic cover Always replace the cover after servicing the equipment SPECIFICATIONS Electrical Ratings Operating Voltage 5 0 25 VDC Supply Current 30mA Max 5 VDC Logic...

Страница 8: ...uction Manual Product Introduction 6 PULSER ASSEMBLY PULSER ORIENTATIONS ITEM DESCRIPTION 1 Pulser Mount 2 Pulser 3 Circuit Board Assembly Pulser 4 Top Cover Pulser Assembly 3 1 2 Top View Side View M...

Страница 9: ...Pulser B Phase 2 Bi Directional 9 Pulser C Phase 1 Bi Directional 10 Pulser C Phase 2 Bi Directional 11 Pulser D Phase 1 Bi Directional 12 Pulser D Phase 2 Bi Directional 13 Connection Verification Bi...

Страница 10: ...Bennett Pulser Assembly Instruction Manual Product Introduction 8 Page Intentionally Left Blank...

Страница 11: ...2 Each Pulser requires two mounting screws for the mount and 2 mounting screws for the cover to the mount 1 Mount Pulser by aligning roll pin in coupler slot 2 Mount bracket screws to the top of the...

Страница 12: ...d if applicable pulsers for side 2 connect to J1 on the Lower I O Board Note The ribbon cable has notches so the cable cannot be put on backwards Pulser for Product A plugs directly into the Lower I O...

Страница 13: ...draulics area low voltage section of the dispenser The ribbon cable connects to pulser connector J2 to the first pulser in the loop Usually this is the A product If there is more than pulser then anot...

Страница 14: ...s by mail email phone fax or web using the information provided below Note Verbal orders cannot be accepted A signed purchase order must be faxed or emailed to the Bennett Order Entry Department at 23...

Страница 15: ...Bennett Pulser Assembly Instruction Manual Diagnostics Troubleshooting 13 Page Intentionally Left Blank...

Страница 16: ...Bennett Pulser Assembly Instruction Manual Wiring Diagrams 14 SECTION 5 WIRING DIAGRAMS...

Страница 17: ...Bennett Pulser Assembly Instruction Manual Wiring Diagrams 15...

Страница 18: ...Bennett Pulser Assembly Instruction Manual Page Intentionally Left Blank...

Страница 19: ...Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...

Отзывы: