Bennett 1K Series Скачать руководство пользователя страница 9

 

 

9 

135442 Rev A 9-18-17 

Use the table below to determine how many wires your communication console requires and the connection points for this type of 
communication. Note: Connections will vary depending on the dispenser model and options. 

1-SIDED DISPENSER COMMUNICATION = 2 FIELD WIRES (REQUIRED) 

QTY 

Description 

To Board 

To Connector 

1  

Orange #18 Wire – Bennett Current Loop Communication (+positive) 

Current Loop Personality Module 

TS1, Terminal 1 

1  

Yellow #18 Wire - Bennett Current Loop Communication (-negative) 

Current Loop Personality Module  

TS1, Terminal 2 

2-SIDED DISPENSER COMMUNICATION = 4 FIELD WIRES (REQUIRED) 

QTY 

Description 

To Board 

To Connector 

1  

Orange #18 Wire –Bennett Current Loop Communication (+positive) 

Current Loop Personality Module 

TS1, Terminal 1 

1  

Yellow #18 Wire  - Bennett Current Loop Communication (-negative) 

Current Loop Personality Module  

TS1, Terminal 2 

Orange #18 Wire –Bennett Current Loop Communication (+positive) 

Current Loop Personality Module 

TS2, Terminal 1 

Yellow #18 Wire  - Bennett Current Loop Communication (-negative) 

Current Loop Personality Module  

TS2, Terminal 2 

GENERIC CURRENT LOOP  FUEL COMMUNICATION ( 121982)  

To be used with Gilbarco Passport, VeriFone Commander, Wayne Fusion, and Wayne Nucleus remote consoles. Generic Current Loop uses a 2-wire 
protocol. Note: Refer to the wiring diagram included in the dispenser for wire, shunts, and field jumper wire connections. 

Use the table below to determine how many wires your communication console requires for this type of communication. Note: Connections will 
vary depending on the dispenser model and options. 

1-SIDED DISPENSER COMMUNICATION = 2 FIELD WIRES AND 1 SHUNT (REQUIRED) 

QTY 

Description 

To Board 

To Connector 

1  

Orange #18 Wire - RS485 Communication (+positive) 

Current Loop Personality Module 

TS1, Terminal 1 

1  

Yellow #18 Wire - RS485 Communication (-negative) 

Current Loop Personality Module 

TS1, Terminal 2 

Shunt 

Current Loop Personality Module 

Top 2 Pins at JP1 

2-SIDED DISPENSER COMMUNICATION = 2 FIELD WIRES, 1 FIELD JUMPER, AND 2 SHUNTS (REQUIRED) 

QTY 

Description 

To Board 

To Connector 

1  

Orange #18 Wire - RS485 Communication (+positive) 

Current Loop Personality Module 

TS1, Terminal 1 

1  

Field Jumper Wire 

Current Loop Personality Module 

TS1, Terminal 2 to TS2, Terminal 1 

Yellow #18 Wire  - RS485 Communication (-negative) 

Current Loop Personality Module 

TS2, Terminal 2 

Shunt (All POS systems except Excentus) 

Current Loop Personality Module 

Top 2 Pins at JP1 and JP2 

Shunt (Use only if an Excentus POS system is used) 

Current Loop Personality Module 

Bottom 2 pins at JP1 and JP2 

RS-485 FUEL COMMUNICATI ON (121992)  

To be used with Allied NeXGen remote consoles. The RS485 uses a 2-wire protocol. RS-485 wires should be twisted together no less than 3 turns 
per foot to reduce the effects of electrical noise on the communication circuit. Bennett highly recommends the use of twisted wires. Note: Belden 
shielded cable is accepted but the “drain” must not be terminated. 

COMMUNICATION = 2 FIELD WIRES 

QTY 

Description 

To Board 

To Connector 

Orange #18 Wire - RS485 Communication (+positive) 

RS485 Personality Module 

TS1, Terminal 1 

Brown #18 Wire  - RS485 Communication (-negative) 

RS485 Personality Module 

TS1, Terminal 3 

 

CARD READER COMMUNICATION (OPTIONAL)  

Bennett Dispensers can interface with many POS terminals as well as site controllers. Refer to the sections below to determine what type of 
communication is used and what fueling controller is needed for communication. 

 
 
 
 

Field installed communication wires located inside the electrical enclosure of the unit cannot be loose and must be tightly held in place by 
fasteners. RS485 wires should be twisted together no less than 3 turns per foot to reduce the effects of electrical noise on the communication 
circuit. Due to the risk of noise causing possible problems with communication, Bennett highly recommends the use of twisted wires. Note: Belden 
shielded cable is accepted but the “drain” must not be terminated. 

QTY 

Description 

To Board 

To Connector 

Violet #18 Wire - RS485 Communication (+positive) 

CPU Board 

TS1, Terminal 1 

Yellow #18 Wire  - RS485 Communication (-negative) 

CPU Board 

TS1, Terminal 3 

CARD READER COMMUNICATION 
RS485 
Ethernet 2-Wire – *COMING SOON* 
CAT5e – *COMING SOON* 

Содержание 1K Series

Страница 1: ...e instructions damage can occur to the dispenser Blue and White IMPORTANT means Helpful tips and other recommendations on equipment installation usage and maintenance should be observed PRODUCT OVERVI...

Страница 2: ...roducts 1 2 3 4 or 5 3 Field 4 Number of Hose Outlets 1 2 4 6 or 8 2 Field 5 Blender N Non Blender B Blender E Extended M Mixer M Field 6 Positions 1 One Sided 2 Two Sided 2 Field 7 Payment Not all op...

Страница 3: ...3 135442 Rev A 9 18 17...

Страница 4: ...ser sump to determine if any adjustments are needed prior to mounting the unit onto the island BENNETT RECOMMENDED DISPENSER SUMPS FOR THE PACIFIC SERIES ELECTRONIC DISPENSER FRANKLIN FUELING LM M D 4...

Страница 5: ...5 135442 Rev A 9 18 17 Continued on the next page...

Страница 6: ...roduct line plumbed to inlet position C for alternative product Use 1 product line plumbed to inlet position D for high grade 1X56E1 XXXX 1X56E2 XXXX Use 1 product line plumbed to inlet position A for...

Страница 7: ...7 135442 Rev A 9 18 17...

Страница 8: ...the dispenser s Junction Box Terminate the other end at the main panel breaker box ground bar Do not terminate at the neutral bar of a sub panel or rely on metal conduit for this ground connection Eac...

Страница 9: ...UMPER AND 2 SHUNTS REQUIRED QTY Description To Board To Connector 1 Orange 18 Wire RS485 Communication positive Current Loop Personality Module TS1 Terminal 1 1 Field Jumper Wire Current Loop Personal...

Страница 10: ...alling The individual product wires are identified by the colors used on the wiring diagrams Connect the designated wire to the power board terminal strip position Wiring Remote Sub Pump Control Wires...

Страница 11: ...manager mode selections 5 Once you are in the Manager Mode you can program the dispenser as normal To exit the Manager Mode simply unplug the Manager s Keypad MANAGER S KEYPAD PROGRAMMING The Manager...

Страница 12: ...2 seconds Last Sale 30 Idle 15 Handle State 0 13 Audio Tone Options 3 Combination of option 1 and 2 Audio Tones 14 Price display 1 Flashing 0 Dash Flip 0 15 Fleet Option 1 Enabled 17 Preset Money 0 No...

Страница 13: ...Turn the dispenser power back on WARNING MAKE SURE ALL DISPENSER POWER CIRCUITS FOR REMOTES ONLY ARE ON THE SAME PHASE LEG OF THE BREAKER PANEL OR DAMAGE WILL RESULT CHECK THE PUMP MOTOR CIRCUIT REMOT...

Страница 14: ...14 135442 Rev A 9 18 17...

Страница 15: ...ards toward the submerged pump WARNING TAKE APPROPRIATE MEASURES TO CONTAIN ANY PRODUCT EMERGING FROM THE TEST PORT DISPOSE OF ANY SPILLED PRODUCT IN PROPER MANNER CONSISTENT WITH APPLICABLE LAWS AND...

Страница 16: ...position and seal it THE OPTIONAL CALIBRATION PROCEDURE This procedure assumes that the test can sight glass is graduated in test can percentage units rather than cubic inches or cubic centimeters mi...

Страница 17: ...nel Failed 23 PLSRBS PULSERBS Pulser B Same State Transition Limit Exceeded 24 PLSRBN PULSERBN Pulser B Next State Transition Limit Exceeded 25 PLSRBR PULSERBR Pulser B Reverse Flow 26 PLSRBD PULSERBD...

Страница 18: ...eric Loop Personality Board 2 111171S Pump Handle Switch Pacific 2 122730S Handle Switch Assembly Service Pacific XB 1 113606S Kit Printer w Cab Prog SSP Service 1 RB107336 Circuit Board Assembly Back...

Страница 19: ...19 135442 Rev A 9 18 17 This page is intentionally left blank...

Страница 20: ......

Отзывы: