Bennett 1K Series Скачать руководство пользователя страница 1

 

 

1 

135442 Rev A 9-18-17 

1K SERIES ELECTRONIC QUICK INSTALL GUIDE 

This quick install guide covers the Bennett Pacific eNVy series dispenser specifications, identification, piping and wiring installation, programming 
modes, diagnostic modes, error codes, and spare parts information needed for a Pacific eNVy dispenser built and/or retrofitted with 919 
electronics. Please refer to your technical manuals located on the USB provided for detailed information. 

IMPORTANT SAFETY INSTRUCTIONS 

Bennett Pump Dispensers are to be installed by trained technicians. All technicians must be aware of ALL safety instructions. If you are not a 
Bennett trained technician, please contact Bennett Technical Support at 1-800-423-6638 for training information. 

As you read this guide, please be aware of the following symbols and their meaning. 

Red and White “DANGER” means: If you do not follow the instructions, severe injury or death will occur. 

Orange and Black “WARNING” means: If you do not follow the instructions, severe injury or death can occur. 

Yellow and Black “CAUTION” means: If you do not follow the instructions, damage can occur to the dispenser. 

Blue and White “IMPORTANT” means: Helpful tips and other recommendations on equipment installation, usage, and maintenance should 
be observed. 

PRODUCT OVERVIEW 

STANDARD MODELS   

Products .................................................................................................................................................................................... Up to 4 Products Per Side 
Hoses .............................................................................................................................................................................................. Up to 2 Hoses Per Side 
Unit Type ........................................................................................................................................................................ Straight Grade, Mixer or Blender 
Hydraulics ...................................................................................................................................................................................................... Remote Only 
Flow Rate ....................................................................................................................................................................................................12gpm/ 40lpm 
Inlet / Outlet ............................................................................................................................................. 1-1/2” (3.8cm) dia NPT / .75” (1.9cm) dia NPT 
Protocol ........................................................................................................................................ Bennett Current Loop / Generic Current Loop / RS485 

EXTENDED BLENDER MOD ELS 

Products .................................................................................................................................................................................... Up to 5 Products Per Side 
Hoses .............................................................................................................................................................................................. Up to 4 Hoses Per Side 
Unit Type ........................................................................................................................................................................ Straight Grade, Mixer or Blender 
Hydraulics ...................................................................................................................................................................................................... Remote Only 
Flow Rate ....................................................................................................................................................................................................12gpm/ 40lpm 
Inlet / Outlet ............................................................................................................................................. 1-1/2” (3.8cm) dia NPT / .75” (1.9cm) dia NPT 
Protocol ........................................................................................................................................ Bennett Current Loop / Generic Current Loop / RS485 

 

SPECIFICATIONS 

 

DIMENSIONS

[SK1][LJ2]

 

Standard (without valance) ................................................................................................................................ 49” (width) x 22” (depth) x 91” (height) 
Extended (without valance) ................................................................................................................................ 65” (width) x 22” (depth) x 90” (height) 

ENVIRONMENTAL REQUIR EMENTS 

Operating Temperature ..................................................................................................................................................... -40

C to +65

C / -40

F to 150

F 

Humidity .................................................................................................................................................................................... 0 to 95% Non-Condensing 

POWER REQUIREMENTS 

AC Power Input, Electronic ................................................................................................................................ 120/240VAC, 50/60 Hz. 350 Watts Max. 
DC Power Supply Output .......................................................................................................................................................... +12VDC at 2.0 Amps Max. 

+24VDC at 2.0 Amps Max. 

Lead-Acid Battery Output ......................................................................................................................................................... +12VDC at 5.0 Amp Hours 
Nickel-Cadmium Battery Output
 ..................................................................................................................................... +3.6VDC at 250 Milliamp Hours 

 

 

Содержание 1K Series

Страница 1: ...e instructions damage can occur to the dispenser Blue and White IMPORTANT means Helpful tips and other recommendations on equipment installation usage and maintenance should be observed PRODUCT OVERVI...

Страница 2: ...roducts 1 2 3 4 or 5 3 Field 4 Number of Hose Outlets 1 2 4 6 or 8 2 Field 5 Blender N Non Blender B Blender E Extended M Mixer M Field 6 Positions 1 One Sided 2 Two Sided 2 Field 7 Payment Not all op...

Страница 3: ...3 135442 Rev A 9 18 17...

Страница 4: ...ser sump to determine if any adjustments are needed prior to mounting the unit onto the island BENNETT RECOMMENDED DISPENSER SUMPS FOR THE PACIFIC SERIES ELECTRONIC DISPENSER FRANKLIN FUELING LM M D 4...

Страница 5: ...5 135442 Rev A 9 18 17 Continued on the next page...

Страница 6: ...roduct line plumbed to inlet position C for alternative product Use 1 product line plumbed to inlet position D for high grade 1X56E1 XXXX 1X56E2 XXXX Use 1 product line plumbed to inlet position A for...

Страница 7: ...7 135442 Rev A 9 18 17...

Страница 8: ...the dispenser s Junction Box Terminate the other end at the main panel breaker box ground bar Do not terminate at the neutral bar of a sub panel or rely on metal conduit for this ground connection Eac...

Страница 9: ...UMPER AND 2 SHUNTS REQUIRED QTY Description To Board To Connector 1 Orange 18 Wire RS485 Communication positive Current Loop Personality Module TS1 Terminal 1 1 Field Jumper Wire Current Loop Personal...

Страница 10: ...alling The individual product wires are identified by the colors used on the wiring diagrams Connect the designated wire to the power board terminal strip position Wiring Remote Sub Pump Control Wires...

Страница 11: ...manager mode selections 5 Once you are in the Manager Mode you can program the dispenser as normal To exit the Manager Mode simply unplug the Manager s Keypad MANAGER S KEYPAD PROGRAMMING The Manager...

Страница 12: ...2 seconds Last Sale 30 Idle 15 Handle State 0 13 Audio Tone Options 3 Combination of option 1 and 2 Audio Tones 14 Price display 1 Flashing 0 Dash Flip 0 15 Fleet Option 1 Enabled 17 Preset Money 0 No...

Страница 13: ...Turn the dispenser power back on WARNING MAKE SURE ALL DISPENSER POWER CIRCUITS FOR REMOTES ONLY ARE ON THE SAME PHASE LEG OF THE BREAKER PANEL OR DAMAGE WILL RESULT CHECK THE PUMP MOTOR CIRCUIT REMOT...

Страница 14: ...14 135442 Rev A 9 18 17...

Страница 15: ...ards toward the submerged pump WARNING TAKE APPROPRIATE MEASURES TO CONTAIN ANY PRODUCT EMERGING FROM THE TEST PORT DISPOSE OF ANY SPILLED PRODUCT IN PROPER MANNER CONSISTENT WITH APPLICABLE LAWS AND...

Страница 16: ...position and seal it THE OPTIONAL CALIBRATION PROCEDURE This procedure assumes that the test can sight glass is graduated in test can percentage units rather than cubic inches or cubic centimeters mi...

Страница 17: ...nel Failed 23 PLSRBS PULSERBS Pulser B Same State Transition Limit Exceeded 24 PLSRBN PULSERBN Pulser B Next State Transition Limit Exceeded 25 PLSRBR PULSERBR Pulser B Reverse Flow 26 PLSRBD PULSERBD...

Страница 18: ...eric Loop Personality Board 2 111171S Pump Handle Switch Pacific 2 122730S Handle Switch Assembly Service Pacific XB 1 113606S Kit Printer w Cab Prog SSP Service 1 RB107336 Circuit Board Assembly Back...

Страница 19: ...19 135442 Rev A 9 18 17 This page is intentionally left blank...

Страница 20: ......