8
9
To exit the programming procedure wait 10 sec or press the PGM button for 1 sec, the Power LED will
return to normal blinking at 3 sec intervals.
Remote Learning of a transmitter
If one transmitter has already been memorised others can be memorised without having to access the
control unit as follows:
- Press the hidden key on the memorised transmitter, the courtesy light will start blinking at 1 sec
intervals.
- Within 10 sec press the button of a new transmitter to memorise with Step by Step functioning, the
courtesy light will go out.
Cancelling all transmitters from the memory
- Keep the PGM button pressed for 15 sec, the Power LED will start blinking rapidly and when it goes out
the memory has been erased.
- Release the PGM button, the memory has been cancelled and the Power LED will return to normal
blinking at 3 sec intervals.
N.B.:
For safety reasons, transmitters cannot be memorised during the open/close cycles of the motor.
When entering the memorise transmitter procedure, if the Power LED gives a prolonged blink and then
goes out, this signals that the receiver memory is full and no other transmitters can be memorised or that
the transmitter is not compatible.
www.ga