18
LOGIC (
LOG
)
MENU
FUNCTION
ON-OFF-(Default)
MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(OFF)
IBL
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands have
no effect during the opening phase.
Off: multi-flat function disabled.
(OFF)
IBCA
During the TCA phase, the PP controls are enabled or disabled.
On: PP controls are disabled.
Off: PP controls are enabled.
(OFF)
SCL
The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes the
automatic closure after 3 s.
If the photocell is activated during the opening phase, the operation is completed
and closure starts after 3s
Off: disabled rapid closure.
(OFF)
PP
The operating mode of “P.P. Push button” and of the transmitter are selected.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the
starting of the motor.
Off: disabled forewarning flashing light.
(OFF)
HTR
The Service Man function is enabled or disabled.
On: Service Man operation. The OPEN/CLOSE push buttons should be kept
pressed for the entire operating time.
Off: Automatic operation.
(OFF)
LTCA
During the TCA time, the blinker is enabled or disabled.
On: Enables blinker.
Off: Disables blinker.
(OFF)
ENC
The Encoder is enabled or disabled.
On: Activated Encoder.
Off: Not activated Encoder. The encoder only detects the door/gate stroke. In the
event of maintenance operations, it is advisable to deactivate it only temporarily.
(ON)
Pho1
The PHOT 1 input is enabled or disabled in the opening phase.
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
(OFF)
Pho2
As per PH01, but referred to PHOT 2 input.
(OFF)
Pho3
As per PH01, but referred to PHOT 3 input.
(OFF)
Pho4
As per PH01, but referred to PHOT 4 input.
(OFF)
tst1
The check on the photocell connected to PHOT1 input is activated or deactivated
Before operation, the control unit checks the switching of the photocell contact.
If the checks are not successful, the door/gate will not move.
On: activated check on photocell.
Off: deactivated check on photocell.
(OFF)
tst2
As for TST1, but referred to PHOT2 input
(OFF)
tst3
As for TST1, but referred to PHOT3 input
(OFF)
tst4
As for TST1, but referred to PHOT$ input
(OFF)
MINV
The opening direction of the motor is selected (see Fig. 4):
On: Right side motor mount
Off: Left side motor mount
(OFF)
CVAR
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
(OFF)