background image

 

 

 
 
 
 
 
 
 
 
Using the chlorinator 

 
1. When the chlorinator is connected to the faucet, adjust the water flow with the valve to ensure 

that enough water flows through the salt chlorinator. 

2. Before use, ensure that the salt concentration of the pool water is within the normal operating 

range (3.5- 4.5 kg of salt per m³), otherwise it may shorten the life of the Titanium cell. 

3.  The display shows the current water temperature. Press the Power / Operate button, the 

operation light will change from red to green and the chlorinator will start working: Note: The 
chlorinator can only operate if the water level detector detects the presence of sufficient 
water flow . 

4. By pressing the "+" or "-" button, users can adjust the rate of chlorine creation as needed; users 

can use level 1-5, 1 level is the smallest and 5 level is the highest. The higher the level, the 
faster the chlorine is produced. 

5. Parameter check: press the acceleration key several times while the chlorinator is off to look up 

various parameters below: 

 

 

① Internal temperature chlorinator

 

             

② Water temperature

 

             

③ Input voltage

 

             

④ Version number

 

             

⑤ Time period of continuous operation; the system automaticall

y exits the application after 

3 seconds  

6. Time setting for continuous operation: press the acceleration key 5 times while the machine is 

turned off to display the time period of continuous operation. Change the time periods of 
continuous operation by pressing '+' or '-'.  

The time period ranges from 1-24 hours 

(and then shut off) after it is turned on. After this cycle, the chlorinator stops for 12 hours and 
turns on again for 12 hours. 

In case you use the control option "RX TIME", the setting of the chlorinator should be at least as 

long, than the selected time. 

 

IMPORTANT: 

THE CHLORINATOR IS PRESET FOR 12 HOURS CONTINUOUS 

OPERATION, IF 24 HOURS NON-STOP OPERATION IS REQUIRED, THE TIME 
FOR CONTINUOUS OPERATION MUST BE SET TO 24; THE SYSTEM WILL 
AUTOMATICALLY EXIT THE SETTING AFTER 3 SECONDS.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ZALX0030

Страница 1: ...ZLAX0016 ZLAX0020 en ZALX0030 EC8 12 16 20 and 30...

Страница 2: ...HS Salt electrolysis 1 Table of content 2 Specifications 4 Salt electrolysis installation 5 Structure diagram 7 Using the chlorinator 8 Warnings 14...

Страница 3: ...eatures Durable the materials used are chlorine acid sulfuric acid salt and alkali resistant They can withstand long term exposure to pool water even with salt for salt electrolysis Simple operation t...

Страница 4: ...ssories such as heater UV lamp filter etc It is recommended that the installation of the water treatment unit be in bypass configuration Install the water treatment unit on a solid base or against the...

Страница 5: ...line suitable for PVC bonding The chlorinator should be installed in a well ventilated area to allow it to cool properly Do not install in an area where the electronic components of the chlorinator m...

Страница 6: ...uch as automatic reset self cleaning lime removal and malfunction alarm Product Distinctive Facts Design for easy access to the titanium polar plate during installation and maintenance Users can choos...

Страница 7: ...Structure diagram Model Chlorine productio n Ideal business location EC8 8g h unit suitable for swimming pools 40 m EC12 12g h unit suitable for swimming pools 60 m EC16 16g h unit suitable for swimmi...

Страница 8: ...roduced 5 Parameter check press the acceleration key several times while the chlorinator is off to look up various parameters below Internal temperature chlorinator Water temperature Input voltage Ver...

Страница 9: ...ror code if a problem occurs 2 Level indicator light 1 light stands for level 1 2 light stands for level 2 5 lights stand for 5 levels 3 Button for level control of chlorine production 4 boost indicat...

Страница 10: ...k that the water level detector is attached Check if water is leaking or if air is present If water is present wash the water level detector E4 Salt concentration is too high Normal operation requires...

Страница 11: ...e fault must be resolved manually change the power supply E9 Electrode does not work properly The fault must be remedied manually contact supplier for repair EA Electrode defective The fault will have...

Страница 12: ...salt with approval number as a precursor of biocides of the country in which the unit is used The sodium chloride NaCl in the salt must be at least 99 6 1 3 Adding the right amount of salt Most swimmi...

Страница 13: ...nly way to lower the salt concentration is to drain some of the pool water and replace it with fresh water 1 6 To reduce the loss of chlorine due to UV radiation on the water of the outdoor pool you s...

Страница 14: ...safety glasses when working on the installation Disconnect power when working on the installation NEVER make any adjustments inside the dispensing equipment If you are not familiar with the pool filt...

Отзывы: