Breakout Board Installation Guide

 

 

 

Nicolas Benezan, Stauffenbergstr. 26, 72108 Rottenburg 
Phone: +49 (0) 7457/946365 0 benezan-electronics.de 

Page 

Netbob1 installation.docx22.09.2020 

 

Safety Instructions 

The  interface  board  may  only  be  installed  and  put  into  operation  by  qualified  personnel. 
Please read the operating instructions carefully and  follow  all instructions exactly. Improper 
installation or operation of the device can cause damage to the electronics or the machine and 
can result in dangers to the health of the operating personnel.  

Depending  on  the  hazard  potential  of  the  machine,  additional  safety  measures  may  be 

required,  such  as  door  interlocks  and  standstill  monitoring.  As  a  rule,  such  safety  functions 
must  be  implemented  purely  electromechanically  with  external  circuits  (not  included  in  the 
scope  of  delivery)  and  must  not  depend  solely  on  software  and  PC  hardware.  The  system  manufacturer,  who  assembles  the 
interface board and other components to form the overall system, and the system operator are responsible for compliance with  the 
legal regulations. 

Connections 

The connections of all terminals are numbered from left to right. The pins of the SUBD connector and the pins for the jumpers are 
numbered from top to bottom. 

Please note

: The contacts of the RJ45 sockets are numbered from bottom (1) to top (8). 

 

 

 

3  4 

3  4 

Net- 

work 

1  2  3  4  5  6 

1  2  3  4  5 

1  2  3  4  5  6  7  8 

1  2  3  4  5  6 

Relay 1  Relay 2 

ext. LEDs 

ST7 

JP4 / JP3 

Содержание Beamicon2 IoExt1

Страница 1: ...ll known limitations of step frequency and timing problems are a thing of the past The board can be adjusted to many different configurations Depending on the selected configuration additional functio...

Страница 2: ...afety measures may be required such as door interlocks and standstill monitoring As a rule such safety functions must be implemented purely electromechanically with external circuits not included in t...

Страница 3: ...input Power supply 5 pole terminal X1 top right No Description 1 5V output max 150mA 2 Ground 0V 3 12V output max 0 3A 4 Ground 0V 5 24V input 15 75V Relay outputs 6 pole terminal X4 bottom right No D...

Страница 4: ...re reliable operation however the following rules must be observed The breakout board must be connected either directly to the PC or to the first switch after the PC A further switch may only be added...

Страница 5: ...and jumpers 10 11 must be plugged in see also Chapter 4 Configuration If the power stage is to remain active during an emergency stop recommended shorter braking distance jumpers 7 11 must remain open...

Страница 6: ...against payment Relay outputs The relay outputs 1 and 2 can be used to switch 230V consumers such as spindle motor coolant pump or chip extractor The current consumption must not exceed 8A per relay o...

Страница 7: ...ith old thyristor controllers whose speed input is partially connected to the mains voltage These must not be used If in doubt please refer to the data sheet of the frequency inverter or speed control...

Страница 8: ...Breakout Board Installation Guide Nicolas Benezan Stauffenbergstr 26 72108 Rottenburg Phone 49 0 7457 946365 0 benezan electronics de Page Netbob1 installation docx22 09 2020 No Description Power Rea...

Страница 9: ...d in detail in the Beamicon2 software manuals Therefore only the special features of the breakout board will be discussed here The easiest way to configure the software is to select the default parame...

Страница 10: ...tep signals are disabled When using stepper motor output stages the current reduction signal must be applied to the enable pin if they have a current reduction input This is always active when all dri...

Страница 11: ...ent at the relay outputs X4 8 Aeff Voltage at relay Holding brake 30 V Current at relay holding brake 5 Aeff Electrical connection values Parameters min max Unit Operating voltage nominal 24V 15 75 V...

Страница 12: ...ifiers are used jumper JP4 4 5 must be plugged in If less than 3 power amplifiers are connected a dummy plug with a bridge between pin 7 and 8 must be inserted for the missing axes Is the emergency st...

Страница 13: ...ule selected if several modules are in the network 4 LED Ready green right does not light up a ChargePump signal not assigned or module is not connected b Software not started or running in demo mode...

Отзывы: