Operation Manual
EL240.128.45 Display
Beneq Oy
Olarinluoma 9
Tel. +358 9 7599 530
VAT ID FI19563372
FI-02200 Espoo
Fax +358 9 7599 5310
www.beneq.com
Finland
www.lumineq.com
Date: February 13, 2017
Document number: ED000810B
Page | 14
3.8.1
Required register settings and configuration items
The module uses one 32 k x 8 SRAM for all CG and display memory.
W/S, bit 3 of the P1 byte of the SYSTEM SET instruction, is set to 0 for a single
drive panel.
DR, bit 7 of the P1 byte of the SYSTEM SET instruction, is set to 0 to turn off the
additional output cycle of the shift clock.
The recommended SYSTEM.SET parameter values for a frame rate of 240 Hz are
(P1 through P8) in hex: 32, 07, 07, 1D, 23, 7F, 1E, 00.
P5 must not be less than 23 to guarantee that minimum line period requirement
of the display is achieved (32.5
µ
s).
The READY flag is high during extra line times, so P6 should be over 7F if the
READY flag is used. After the falling edge of the READY flag, there is min. 3.5
s
time to end the display memory write cycle.
Oscillator frequency to RAiO RA8835A is 10 MHz.
3.9
Environmental
Table 9. Environmental characteristics
Temperature
Operating
-40 °C to +70 °C
Operating survival
-40 °C to +85 °C
Non-operating
-50 °C to +105 °C After 12 hours at -50 °C, display must be at
-40°C for 1 hour prior to power on.
Humidity
Operating
to 93 % RH max @ 40 ºC, per IEC 60068-2-78 (non-condensing)
Non-operating
to 95 % RH max @ 25-55 °C, per IEC 60068-2-30 (condensing)
Altitude
Operating/non-operating 0 to 18,000 m per IEC 60068-2-13
Vibration
Operating/non-operating 0.02 g
2
/Hz, 5-500 Hz, 30 minutes on each axis,
per IEC 60068-2-64, Random
Mechanical shock
Operating/non-operating 100 g, 6 ms duration (half sine wave), three shocks per
surface (6), tested per IEC 60068-2-27, Test Ea
Thermal shock
40 °C for 30 min., room temperature for ~3 min., then 85 °C for
30 min. Cycle repeated five times.
Displays are non-operating during the tests performed per IEC 60068-2-14. Test Na.