Operation Manual
EL640.400-C2, -C3 and -
CD3 Display
Beneq Products Oy
Olarinluoma 9
Tel. +358 9 7599 530
VAT ID FI25115461
FI-02200 Espoo
Fax +358 9 7599 5310
www.beneq.com
Finland
www.lumineq.com
Date: September 23, 2014
Document number: ED000821B
Page | 8
Table 3. PS2
Position Name
Function
1 SELFTST
Self-test function is selected, if the SELFTEST jumper is OFF. In
self-test, the input video data at VID and TVID inputs are displayed
asynchronously without any other input signals.
2 F2040
200 lines mode. All data is repeated in two consecutive rows.
Normally should be installed.
3 DCONFIG
The two-bits-parallel mode is selected if this jumper is OFF (see
page 10).
4 reserved
Reserved, do not insert jumper.
When shipped from the factory, the jumpers PS2/1, 2 and 3 are set.
3.8
Input specifications
Table 4. Input specifications
Parameter
Symbol Min.
Typ.
Max.
Absolute max.
rating
Logic input HIGH
2 V
V
cc1
+ 0.5 V
Logic input LOW
0.8 V
–0.5 V
Logic supply voltage
V
cc1
4.75 V 5.0 V 5.25 V
6 V
Logic supply current at 5 V
I
cc1
—
—
0.2 A
Display Supply voltage
V
cc2
11 V
—
30 V
33 V
Supply current at 12 V
I
cc2
0.8 A
1.6 A
Supply current at 12 V
(LOWPWR)
I
cc2
0.5 A
1.0 A
Power consumption 5 V /
12 V
11 W
20 W
Power consumption 5 V /
12 V (LOWPWR)
7 W
13 W
Operating conditions: Frame rate 70 Hz, ambient temperature 25 °C.
NOTE:
Absolute maximum ratings are those values beyond which damage to the device may
occur. The minimum and maximum specifications in this Operations Manual should be met,
without exception, to ensure the long-term reliability of the display. Beneq does not