HDS-14LSX / HDS-14LSXE Lifts
13
P/N 5900162 — April 2018 — Rev. F3
Planning for Electrical Work
You will need to have a licensed, certified electrician available at some point during the installation.
⚠
DANGER
All wiring
must
be performed by a licensed, certified electrician.
Notify your electrician in advance so that they come prepared with an appropriate cable for connecting
to the power source, a plug for the Power Unit, a Power Disconnect Switch, and a Thermal Disconnect
Switch. Refer to
Contacting the Electrician
for more information.
Your electrician needs to:
•
Connect an electric power source to the Power Unit
. A power source is required. Your
electrician will need to put an appropriate plug on the wiring on the Power Unit and provide a
power cable from the power source to the Power Unit.
•
Install a Power Disconnect Switch
. Ensures you can quickly and completely interrupt
electrical power to the Lift in the event of an electrical circuit fault, emergency situation, or when
equipment is undergoing service or maintenance. Put it within sight and reach of the Lift operator.
•
Install a Thermal Disconnect Switch
. Ensures the equipment shuts down in the event of an
overload or an overheated motor.
Selecting a Location
When selecting the location for your Lift, consider:
•
Architectural plans
. Consult the architectural plans for your desired installation location. Make
sure there are no issues between what you want to do and what the plans show.
•
Available space
. Make sure there is enough space for the Lift: front, back, sides, and above.
Refer to
Specifications
for measurements.
•
Overhead obstructions
. Check for overhead obstructions such as building supports, heaters,
electrical lines, low ceilings, hanging lights, and so on.
You do not want the vehicles on the
Lift hitting obstructions
. As a general rule, the Lift location should have 80 inches of height
plus the height of the tallest vehicle you plan on raising.
•
Side and front clearances
. You must leave room around the Lift. Leave at least five feet (60
inches) clear on each side, three feet (36 inches) clear on the Front of the Lift (you will need more
for the alignment equipment if you have an Aligner), and no obstructions at all at the Rear of the Lift
(so you can safely drive vehicles onto the Runways).
•
Power
. You need a 220 VAC power source available for the Power Unit.
•
Outdoor installations
. Your Lift is approved for indoor installation and use only. Outdoor
installation is prohibited.
•
Floor
. Only install the Lift on a flat, concrete floor; do not install on asphalt or any other surface.
The surface must be level; do not install if the surface has more than three degrees of slope.
⚠
WARNING
Installing your Lift on a surface with more than three degrees of slope could lead to
injury or even death. Only install the Lift on a level floor (defined as no more than 3/8
of an inch difference over the installation area). If your floor is not level, consider
making the floor level or using a different location.
•
Shimming
. If your concrete floor is not completely level, you can use Shims under the bases of
the Posts, as needed, to level the Lift.
NOTICE
Because your Lift is an Alignment Lift, you want to
make it as level as possible
.
You can level you Lift in two ways: first, by shimming the Posts and second by
Содержание HDS-14LSX
Страница 9: ...HDS 14LSX HDS 14LSXE Lifts 9 P N 5900162 April 2018 Rev F3 Specifications Side View Top View ...
Страница 67: ...HDS 14LSX HDS 14LSXE Lifts 67 P N 5900162 April 2018 Rev F3 Wiring Diagrams Power Unit 1 Power Unit 2 ...
Страница 68: ...HDS 14LSX HDS 14LSXE Lifts 68 P N 5900162 April 2018 Rev F3 Labels ...
Страница 69: ...HDS 14LSX HDS 14LSXE Lifts 69 P N 5900162 April 2018 Rev F3 ...
Страница 70: ...HDS 14LSX HDS 14LSXE Lifts 70 P N 5900162 April 2018 Rev F3 ...
Страница 71: ...HDS 14LSX HDS 14LSXE Lifts 71 P N 5900162 April 2018 Rev F3 Parts Drawings ...
Страница 72: ...HDS 14LSX HDS 14LSXE Lifts 72 P N 5900162 April 2018 Rev F3 ...
Страница 73: ...HDS 14LSX HDS 14LSXE Lifts 73 P N 5900162 April 2018 Rev F3 ...
Страница 74: ...HDS 14LSX HDS 14LSXE Lifts 74 P N 5900162 April 2018 Rev F3 ...
Страница 75: ...HDS 14LSX HDS 14LSXE Lifts 75 P N 5900162 April 2018 Rev F3 ...
Страница 76: ...HDS 14LSX HDS 14LSXE Lifts 76 P N 5900162 April 2018 Rev F3 ...
Страница 77: ...HDS 14LSX HDS 14LSXE Lifts 77 P N 5900162 April 2018 Rev F3 ...
Страница 78: ...HDS 14LSX HDS 14LSXE Lifts 78 P N 5900162 April 2018 Rev F3 ...
Страница 79: ...HDS 14LSX HDS 14LSXE Lifts 79 P N 5900162 April 2018 Rev F3 Maintenance Log ...
Страница 80: ...1645 Lemonwood Drive Santa Paula CA 93060 USA 2018 BendPak Inc All rights reserved bendpak com ...