background image

3

 REFER TO THE MANUAL THAT CAME WITH THE 

LIFT FOR PROPER SAFETY AND OPERATING 

INSTRUCTIONS. READ, FOLLOW AND 

UNDERSTAND THE OPERATING MANUAL BEFORE 

OPERATING ANY AUTOMOTIVE LIFT

1.  With no vehicle loaded on the lift, raise lift all the way 

off the ground and rest it on the top safety lock position.

2.  Ensure that the lift is resting on the safeties.

3.  Disconnect the Hydraulic Power Unit on the lift from 

the electrical power source.

4.  The Adjustable Limit Microswitch Kit will be installed 

on the inside of the Powerside Runway near the ram end 

of the Hydraulic Cylinder.

5.  Select location for the Limit Switch Kit on the side of 

the Runway adjacent to the Hydraulic Power Unit.

5.  Once desired location is selected, use the Limit 

Switch Bracket mounting holes as guides and drill four 

holes in the side of the Runway. (See Fig 1.1)

6.  Wire the microswitch prior to mounting Kit inside the 

Runway. Refer to the wiring diagram on page 4.

7.  Mount the Limit Switch Kit on the inside of the Run-

way using the four M6 Bolts, Nuts and Washers. Make 

sure the microswitch lever is facing as shown.

(See Fig 1.2)

8.  Route the electrical cable through the hose retainers 

on the underside of the Powerside Runway and through 

the flex hose to the power unit. Refer to the wiring dia

-

gram on the following page for power unit connection.

DO NOT PROCEED  OR GO NEAR THE LIFT WORK 

AREA UNLESS VISUAL CONFIRMATION IS MADE OF 

ALL SAFETY LOCKS. ALL LOCKS MUST BE ENGAGED 

BEFORE PROCEEDING. FAILURE TO COMPLY WITH 

THESE INSTRUCTIONS MAY RESULT IN SEVERE 

PERSONAL INJURY OR DEATH.

DO NOT  PERFORM ANY MAINTENANCE OR

 INSTALLATION OF ANY COMPONENTS WITHOUT 

FIRST ENSURING THAT ELECTRICAL POWER HAS 

BEEN DISCONNECTED AT THE SOURCE OR PANEL 

AND CANNOT BE RE-ENERGIZED UNTIL ALL

 MAINTENANCE AND/OR INSTALLATION

 PROCEDURES ARE COMPLETED.

ALL WIRING MUST BE PERFORMED 

BY A LICENSED ELECTRICIAN.

Fig. 1.1

Fig. 1.2

M6 Hardware

Содержание 5900181

Страница 1: ...or repair this equipment without reading this manual and the important safety instructions shown inside 1645 Lemonwood Dr Santa Paula CA 93060 USA Toll Free 1 800 253 2363 Tel 1 805 933 9970 Fax 1 805 933 9160 www bendpak com Keep this operation manual near the machine at all times Make sure that ALL USERS read this manual ADJUSTABLE LIMIT MICROSWITCH OPTION FOR BENDPAK HD 9 4 POST LIFTS PLEASE RE...

Страница 2: ...t initial function t Read and follow the safety instructions Keep them readily available for machine operators t Make certain all operators are properly trained know how to safely and correctly operate the unit and are properly supervised t Allow unit operation only with all parts in place and operating safely t Carefully inspect the unit on a regular basis and perform all maintenance as required ...

Страница 3: ...microswitch prior to mounting Kit inside the Runway Refer to the wiring diagram on page 4 7 Mount the Limit Switch Kit on the inside of the Run way using the four M6 Bolts Nuts and Washers Make sure the microswitch lever is facing as shown See Fig 1 2 8 Route the electrical cable through the hose retainers on the underside of the Powerside Runway and through the flex hose to the power unit Refer t...

Страница 4: ...ards the front of the lift the Cylinder Guide Assembly or the Kit will not function properly 13 Test the kit by raising the lift off of the safeties and continue raising until the Cylinder Guide Assembly Arm contacts the microswitch lever and stops the system If the system does not stop at the maximum desired height lower the lift onto the safeties and check the position of the microswitch It may ...

Страница 5: ...3660mm A SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN SIZE MATERIAL A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED NOTE UNLESS OTHERWISE SPECIFIED TM 5210235 HD SERIES ADJUSTABLE LIMIT...

Страница 6: ...6 For Parts Or Service Contact BendPak Inc Ranger Products 1645 Lemonwood Dr Santa Paula CA 93060 Tel 1 805 933 9970 Toll Free 1 800 253 2363 Fax 1 805 933 9160 www bendpak com p n 5900181 ...

Отзывы: