28
Electrical Requirements
Electrical Requirements - Side Object Detection (SOD)
The Side Object Detection (SOD) system consists of two components: a Side Sensor (SS) and a Side Sensor Display (SSD).
Power Requirements
•
Operating Voltage: +9-32Vdc
•
Power Current: Not to exceed 0.25 amps
•
Recommended Fuse: 1 amp
Wiring Schematics
Notes:
All wires to be cross link GXL or equivalent unless otherwise speci
fi
ed.
Use approved J1939 cable.
Interconnection Table
From
To
Code
Gauge
J2-1
T2
Ignition
18 AWG
J2-2
T3
Chassis Ground
18 AWG
J2-3 J1-3 Communication
18
AWG
J2-4 J1-1 Power
18
AWG
From
To
Code
Gauge
J2-5
J1-2
Signal Ground
18 AWG
J2-6
No Connection
–
18 AWG
J1-4
T1
Right Turn Signal*
18 AWG
*
* For this example, the right turn signal is used, however, the left turn signal could also be used for a Side Sensor installed on the driver
side of the vehicle.
1
2
3
4
5
6
Side Sensor
Connector Rear
P2 SOD
ODU P1
1
2
3
4
Connector Rear