Technical data
12
RFID113_D00303_00_M_XXEN/05.2018
3. Technical data
3.1
Tabular data
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated voltage ........................................................................................................................................................ 12.5 V
Overvoltage category.....................................................................................................................................................III
Pollution degree .............................................................................................................................................................3
Rated impulse withstand voltage........................................................................................................................... 800 V
Rated insulation voltage ........................................................................................................................................ 12.5 V
Altitude..................................................................................................................................................≤ 2000 m AMSL
Rated voltage/rated current
Rated voltage ......................................................................................................................................................DC 3.3 V
Rated voltage tolerance......................................................................................................................................... ±5 %
Rated current..........................................................................................................................................................70 mA
Frequency
Radio frequency ..............................................................................................................................................13.56 MHz
Environment/EMC
EMC ......................................................................................................................................................IEC 61851-1/-22
Operating temperature ........................................................................................................................... -30…+70 °C
Climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ............................................3K5 (except condensation, water and formation of ice)
Transport (IEC 60721-3-2) ....................................................................................................................................... 2K3
Long-term storage (IEC 60721-3-1) ........................................................................................................................ 1K4
Mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .............................................................................................................................. 3M4
Transport (IEC 60721-3-2) ...................................................................................................................................... 2M2
Long-term storage (IEC 60721-3-1) ....................................................................................................................... 1M3
Connection
Connection to charge controller ................................................................................................................via RJ45 cable
Maximum cable length......................................................................................................................................... < 1 m