Performance Plots
Figure 1 – THD vs. Output Power - 4-Ohm Load
This plot shows the extraordinary THD performance of the
AHB2
. The feed-forward error correction
circuits keep the output nearly distortion free.
The magenta curve is the output power. Power is shown on the right-hand vertical scale.
The green trace is the THD measured at the output of the left channel when loaded with 4-Ohms.
The red trace is the THD measured at the output of the right channel when loaded with 4-Ohms.
THD is shown on the left-hand scale.
The stair steps are caused by the THD within the AP2722. This stair stepping demonstrates that the
AHB2
is at or below the measurement limits of the AP2722 test set, even when the
AHB2
is
driving a heavy load.