Handy Wireless Scanner
14
U
SER
M
ANUAL
Default Parameters
The factory default setting table gives the default settings of all the programmable
parameters. The default settings will be restored whenever the "Reset" programming
label is scanned and the scanner is in programming mode. Default values are highlighted
in grey background in the settings.
Factory Default Setting
Parameter
Default
Radio communication
Wireless host
Dongle
Pairing mode
Unlocked
Data transmit
Normal
Radio protocol timeout
5 seconds
Power off timeout
20 minutes
Encryption
Enable
Dongle Host
RS-232 communication
Baud rate
9600
Parity
none
Data bits
8
Stop bit
1
RTS/CTS
off
Terminator
<CR><LF>
Keyboard Wedge Communication
Terminator
PC/AT
Keyboard
US keyboard
Terminator
Enter(Alpha numeric)
USB Communication
Terminator
Enter
Code mode
Scan code
Keyboard
US keyboard
Wand Emulation
Wand emulation speed
Normal
Data output
Black=high
Pair contact on dongle
Enable
Scanner
Decoder Selection
Default