Hardwired Installation:

1.   Extend unswitched 24 hour AC supply of rated voltage to a junction box (supplied by others) installed in

 

accordance with all applicable codes and standards. Leave at least 8 inches of slack wire. This circuit should NOT

 

be energized/live at this time.

2.   Open the unit by unscrewing the cover screws on the sides of the unit (Figure 1). The front cover can then be lifted

 

up and removed. 

3.   Unit is supplied with universal spider knockouts and keyhole slots stamped into the back of the cabinet. Knock out

 

the appropriate hole(s) and bring wires through the hole(s) into the cabinet.

4.   Mount the unit securely into place. Do not rely on the electrical box as the only support for the unit. There are two

 

keyhole mounting slots provided in the back of the unit for wall mounting.

5.   Make proper wiring connections between the AC supply and the unit’s transformer per diagram provided (Figure 4).

 

Insulate unused wire!

 Connect ground to supplied green ground wire in accordance with local codes.

 

Reassemble all wire connections and connectors.

 CAUTION! - Failure to insulate unused wire may result in a

 

shock hazard or unsafe condition as well as equipment failure.

6.  For large units the batteries may be shipped separately. Install batteries into the cabinet and complete the

 

appropriate battery connections (Figure 5).

7.   Uncoil the wire lead(s) from the Positive circuit board terminal (+) and connect to the positive terminal connector on the

 

battery (Figure 2).

8.   Route wires and secure in place.

9.   Replace cover and secure cover screws.

10.  Turn on AC line voltage supply.

11.  Position lamps/heads to provide best lighting distribution by loosening head set screws to adjust angle and swivel.

 

Manually rotate or twist head to desired position then tighten set screws to lock position.

INSTRUCTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following: 

1.  READ AND FOLLOW ALL SAFETY INSTRUCTIONS 

2.  For Indoor use ONLY.

3.  Do not let the power cords touch hot surfaces.

4.  Do not install near gas or electric heaters.

5.  Use caution when servicing batteries. Battery acid can cause burns to the skin and eyes. If acid is spilled on skin or eyes, flush acid with 

fresh water and contact a physician immediately.

6.  The equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering.

7.  The use of accessory equipment not recommended by the manufacturer, may cause an unsafe condition, and will void the unit’s 

warranty.

8.  Do not use this equipment for other than its intended purpose.

9.  Servicing of this equipment should be performed by qualified service personnel.

10.  SAVE THESE INSTRUCTIONS! 

STELLA SD (SL-SD)

926000535

OPERATION

ACDC models: 

1.  Sign will illuminate when supplied with power.

CAUTION 

This equipment is furnished with a sophisticated low voltage battery dropout circuit to protect the battery from over-discharge

after it’s useful output has been used. Allow 24 hours recharge time after installation or power failure for full-load testing.

Содержание STELLA SD

Страница 1: ...rminal and connect to the positive terminal connector on the battery Figure 2 8 Route wires and secure in place 9 Replace cover and secure cover screws 10 Turn on AC line voltage supply 11 Position lamps heads to provide best lighting distribution by loosening head set screws to adjust angle and swivel Manually rotate or twist head to desired position then tighten set screws to lock position INSTR...

Страница 2: ...point 2 Check the AC connections to the transformer capacitor assembly Insure that a 120 Volt supply line has not been connected to the 347 Volt transformer capacitor lead wire SIGN COMES ON WHEN BATTERY IS FIRST CONNECTED NO AC This is normal when the battery has enough charge to power the LEDs The sign will remain lit until the battery is discharged SAVE THESE INSTRUCTIONS MAINTENANCE 1 Code req...

Страница 3: ...Bring the wires through the back of the sign and mount the sign securely in place Screw directly to the junction box if possible 5 Connect AC supply per diagram provided Figure 5 Insulate unused wire CAUTION Failure to insulate unused wire may result in a shock hazard or unsafe condition as well as equipment failure 6 Route wires and secure them in place 7 Position the pictogram between the posts ...

Страница 4: ...that the equipment be tested every 30 days for 30 seconds and that written records be maintained Further the equipment is to be tested once a year for the duration required as per Code The equipment is to be repaired whenever the equipment fails to operate as intended during the duration test Written records of test results and any repairs made must be maintained BeLuce Canada Inc strongly recomme...

Страница 5: ...t the three appropriate canopy mounting holes for your installation Figure 3 4 Secure the canopy to the sign using the supplied 1 inch screws and washer nuts and the snap wire pass thru hole plastic bushing into the wire pass thru hole in the centre of the canopy Figure 2 5 Bring wires through the wire pass thru and connect AC supply as described in step 6 of Wall Mounting instructions above 6 Sec...

Страница 6: ...R 4R3 Tel 905 948 9500 Fax 905 948 8673 email sales beghellicanada com Web http www beghelli com MATERIAL FINISH DRAWN BY DATE SIZE SCALE REV SHEET PART NAME DWG NO REF NO DO NOT SCALE QUADRA RM INSTRUCTION 7 5 2013 PART L D MAINTENANCE 1 Code requires that the equipment be tested every 30 days for 30 seconds and that written records be maintained Further the equipment is to be tested once a year ...

Страница 7: ...s desired Reinsert the red fibre and secure the side of the exit back on with the screwdriver 3 Ceiling and end mount units are provided with a factory installed canopy which is not field adjustable 4 Mount the exit securely in place Screw directly to the junction box if possible If not a universal spider plate may be used to connect the exit to the junction box for exit sign placement adjustment ...

Страница 8: ...plied by others Chassis GND LED Board AC ONLY SIGN Chassis GND GREEN Ground BLACK 120VAC RED 347VAC or ORANGE 200 277VAC WHITE Neutral LED Board AC UNIVERSAL DC SIGN YELLOW Positive 6 to 24VDC PURPLE Negative Emergency Supply FROM Battery Pack SELF POWERED SIGN Chassis GND 24 hours Unswitched Supply GREEN Ground BLACK 105 to 360VAC WHITE Neutral LED Board DUAL UNIVERSAL AC SIGN From Generator OR E...

Страница 9: ... of the sign there are holes for the canopy Knock out the appropriate canopy mounting holes for your installation 3 Secure the canopy to the sign using the supplied nut and align the wire pass thru hole in the frame to the wire pass thru hole in the centre of the canopy 4 Bring wires through the wire pass thru and connect AC supply as described in step 6 of Wall Mount instructions above 5 Secure t...

Страница 10: ... AC ONLY SIGN Chassis GN GREEN Ground BLACK 120VAC RED 347VAC or ORANGE 200 277VAC WHITE Neutral AC UN Chassis GND 24 hours Unswitched Supply GREEN Ground BLACK 105 to 360VAC WHITE Neutral LED Board DUAL UNIVERSAL AC SIGN From Generator OR Emergency Supply BROWN 105 to 360VAC BLUE Neutral NOTE Cap u NOTE Cap unused AC Wire 24 hours Unswitched Supply GREEN Ground BLACK 120VAC RED 347VAC or ORANGE 2...

Страница 11: ...ore performing work on electrical equipment 3 Use caution when servicing batteries 4 Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering 5 The use of accessory equipment not recommended by BeLuce Canada Inc may cause an unsafe condition and will void the unit s warranty 6 Do not use this equipment for other than its intended...

Страница 12: ...oles Install the liquid tight bushing into the large centre knockout with the lock nut 10 Feed the lead wires through the bushing and tighten to complete the liquid tight seal then secure the back plate and housing to the wall Connect wire per wiring diagram provided Caution Failure to insulate unused wire may result in a shock hazard or unsafe condition as well as equipment failure 3 Replace open...

Страница 13: ...ame 2 Frame gasket 3 Die cast backplate 4 O ring 5 Torx tramper proof screws 6 Open face frame 7 Clear lens 8 1 4 20 hex socket cap screw 9 Canopy gasket 10 Canopy 11 Canopy base 12 Mounting screws 13 Bushging 14 Octagon box not supplied 15 Canopy gasket 16 Pictogram 5 4 7 6 2 1 3 12 4 8 12 10 15 11 13 14 9 16 5 4 7 6 2 1 3 12 4 8 12 10 15 11 13 14 9 16 926000543 ...

Страница 14: ...en to complete the liquid tight seal 3 Replace open face frame clear lens and torx screws 4 Apply power MAINTENANCE The equipment is to be tested once a year in accordance with the code requirements The equipment is to be repaired whenever the equip ment fails to operate as intended during the duration test Written records of test results and any repairs made must be maintained BeLuce Canada Inc s...

Страница 15: ...CAUTION Failure to insulate unused wire may result in a shock hazard or unsafe condition as well as equipment failure 10 Hook the other tension spring into the remaining tab and push the assembly back up into the housing until secure 11 Energize power to fixture The LEDs board inside will light and the pictogram faceplate will now be illuminated INSTRUCTIONS IMPORTANT SAFEGUARDS When using electri...

Страница 16: ...ered an agreement to the foregoing UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS INCHES ANGLES 1 2 TOLERANCES X 020 XX 010 XXX 005 XXXX 003 3900 14Th Avenue Markham Ontario L3R 4R3 Tel 905 948 9500 Fax 905 948 8673 email sales beghellicanada com Web http www beghelli com MATERIAL FINISH DRAWN BY DATE SIZE SCALE REV SHEET PART NAME DWG NO REF NO DO NOT SCALE GUIDS STANDARD BACKBOX INSTRUCTION 8 28 2013...

Страница 17: ...he AC supply until indicated 2 Remove plastic bag surrounding sign and put on the plastic gloves located inside the bag before handling the sign directly to protect against smudges and smears TO CHANGE PICTOGRAM IF NECESSARY a Unscrew one end cap Figure 2 b Slide faceplate assembly out of cylinder Figure 2 c Remove buttons Figure 11 d Exchange pictogram e Reinstall buttons press together Figure 12...

Страница 18: ...s GND LED Board AC ONLY SIGN NOTE Cap unused AC Wire GREEN Ground BLACK 120VAC RED 347VAC or ORANGE 200 277VAC WHITE Neutral 24 hours Unswitched Supply Figure 11 Figure 12 ACRYLIC WITH DOTS ON BOTH SIDES BUTTON 4 PIECES ACRYLIC WITH DOTS ON BOTH SIDES STYRENE PICTOGRAM PICTOGRAM BUTTON BUTTON UNDERNEATH FACEPLATE INSERT FLAT HEAD SCREWDRIVER TO POP UP BUTTON CAREFULLY Pictogram PICTOGRAM PICTOGRAM...

Страница 19: ...ce with all Code requirements 2 The lamps listed herein when used according to the instructions with this unit are in accordance with the requirements of CSA Standard C22 2 No 141 Unit Equipment for Emergency Lighting 3 Clean faceplates on a regular basis CAUTION Always turn off AC power before servicing The servicing of any parts should be performed by qualified service personnel The use of repla...

Страница 20: ...ment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering 6 The use of accessory equipment not recommended by BeLuce Canada Inc as it may cause an unsafe condition and will void the unit s warranty 7 Do not use this equipment for other than its intended purpose 8 Servicing of this equipment should be performed by qualified service pers...

Страница 21: ...box 3 Trim plate 5 Pictograms 6 White insert 7 Angle bars x4 8 Bracket 9 Mounting bracket x2 10 Wedge 11 Canopy 12 Bushing 13 6 32 Pan head screw x2 14 6 32 Pan head screw x2 17 6 32 K lock nut x4 16 6 Pan head st screw x2 15 6 32 Flat head screw x2 18 4 Lens 19 Spider plate 20 Spider plate screw kit 21 8 32 K lock nuts x4 22 8 washer x4 8 32 Pan head screw x4 1 Box assembly 2 Back box 3 Trim plat...

Страница 22: ...URFACE WALL MOUNT SURFACE END MOUNT DE SC Wedge Canopy 4 Secure with screw 5 Make electrical connections see Wiring Diagram page 6 6 Adjust the orientation of the spider plate to proper position 5 Thread wires through the spider plate 6 Make electrical connections see Wiring Diagram page 6 7 Adjust the orientation of the spider plate to proper position 19 20 19 20 Octagon box Octagon box Slide len...

Страница 23: ... SCALE 4 Cut for opening 2 Knock out entry hole in back box 3 Install strain relief not supplied 1 2 A COMMON STEPS FOR RECESSED MOUNT DETAIL A SCALE 4 Knock out one entry hole NOTE Follow steps 1 through 8 in Common Mounting Steps before proceeding onto Common Steps for Recessed Mounting 1 2 B B SURFACE WALL MOUNT SURFACE END MOUNT DETAIL A SCALE 4 5 Thread wires through the spider plate 6 Make e...

Страница 24: ...top of box assembly using two pan head screws and k lock nuts 1 2 A B T BAR MOUNT CEILING WALL RECESSED M WALL RECESSED MOUNT 1 2 A B T BAR MOUNT CEILING WALL RECESSED MOUNT WALL RECESSED MOUNT Bracket 1 2 A B T BAR MOUNT CEILING WALL RECESSED WALL RECESSED MOUN Secure with k lock nuts Insert 3 8 pan head screws from inside back box 5 Install cover and lens assembly into box 6 Secure with screw 7 ...

Страница 25: ... up 3 Secure with two pan head screws and k lock nuts A B WALL RECESSED MOUNT A B WALL RECESSED MOUNT Drill out holes Wedge K lock nuts Trim plate Wiring Diagram 1 1 A B CEILING WALL RECESSED MOUNT WALL RECESSED MOUNT 1 2 A 1 2 A Chassis GND LED Board AC ONLY SIGN GREEN Gr BLAC RED 347VAC or ORANGE 20 WHI Chassis GND 24 hours Unswitched Supply GREEN Ground BLACK 105 to 360VAC WHITE Neutral LED Boa...

Страница 26: ...mps listed herein when used according to the instructions with this unit are in accordance with the requirements of CSA Standard C22 2 No 141 Unit Equipment for Emergency Lighting 3 Clean faceplates lenses on a regular basis NOTE Always turn off AC power before servicing The servicing of any parts should be performed by qualified service personnel The use of replacement parts not furnished by BeLu...

Отзывы: