background image

Doc 0203120 rev O

Page 7 of 32

Not subject to issue control when printed

Form-Factor-Matrix, TRUE Models C4.1

Platform (C4.1)

Product 

Name

Model

Data Sheet

MILANO 70

wireless

Batt size 13 zinc air

TRUE 17

TRU1778DW

17523700

TRUE 9

TRU978DW

TRUE 6

TRU678DW

TRUE 3

TRU378DW

MILANO 60

wireless

Batt size 312 zinc air

TRUE 17

TRU1766DW

17657700

TRUE 9

TRU966DW

TRUE 6

TRU666DW

TRUE 3

TRU366DW

This Technical Manual serves to outline the service & postponement procedure for products listed in the form-factor-matrix 

below. Also Data Sheet doc No’s are listed for a more detailed information

Configurations 78 models:

TRUx78DW - Hook with filter

TRUx78DWO (Open) - Thin tube adapt/suitable thin tube

TRUx78DWP (Power) - Hook without filter

See also the DATA SHEET

Configurations 66 models:

TRUx66DW - Hook with filter

TRUx66DWO (Open) - Thin tube adapt/suitable thin tube

Delivered with adult hook with filter. For 60 & 70 models, the hook must always be with filter. If the power version is chosen, 

the hook must always be without filter. The power version cannot be configured to open version with thin tube/adapt

Please also see: 

Doc 0226310 DIRECT WL 2 for information about wireless accessories

Содержание AY276-DW

Страница 1: ...Beltone A S Global Technical Operations http gto gnresound com Lautrupbjerg 7 DK 2750 Ballerup Denmark Technical Manual Beltone MILANO...

Страница 2: ...odules 9 Part list CROS 10 Part list test equipment 11 Part list HSG parts 12 19 Part list thin tubes domes 20 21 Disassemble procedure 22 23 Replacing parts 24 25 Hook hook filter thin tubes domes 26...

Страница 3: ...AY366 DW This Technical Manual serves to outline the service postponement procedure for products listed in the form factor matrix below Note For 60 70 models the hook must always be with filter For th...

Страница 4: ...8 DW This Technical Manual serves to outline the service postponement procedure for products listed in the form factor matrix below Note The hook must always be with filter Open configuration with thi...

Страница 5: ...RIGIN 3 OR378 DVI 400319000 This Technical Manual serves to outline the service postponement procedure for products listed in the form factor matrix below Note The hook must always be with filter The...

Страница 6: ...figuration the metal hook must be chosen without filter See also the DATA SHEET Configurations 60 models MBTE DW 66D MBTE WL MBTE DWO MBTE Open WL Note For 60 70 models the hook must always be with fi...

Страница 7: ...in the form factor matrix below Also Data Sheet doc No s are listed for a more detailed information Configurations 78 models TRUx78DW Hook with filter TRUx78DWO Open Thin tube adapt suitable thin tube...

Страница 8: ...DAI ADAPT2 audio shoe w 3pin euro socket 19901700 Description Part No PIN REMOVAL TOOL PACKED 15502500 MANDREL blue plastic 0490 059 ADULT HOOK without filter 80 17508500 BABY HOOK without filter 80...

Страница 9: ...8 DW 18643000 PSE678 DW 18817400 Service Module 70 80 no silicone caps are mounted Service Module 60 w PB silicone cap glued Part List Programmed Service Modules ASM FRAME ORIGIN C4 1 Part No OR378 DV...

Страница 10: ...IT AUDIO SHOE LARGE 20041100 CROS SUREFIT EUROPLUG SMALL 20040500 CROS SUREFIT EUROPLUG MEDIUM 20040600 CROS SUREFIT EUROPLUG LARGE 20040700 CROS SF EURO PLUG CROS SF AUD SHOE shoe is fixed to the cab...

Страница 11: ...G FIXTURE 16695100 TEST FRAME HI test 16902800 BATTERY PILL 13 70 80 models 17449400 BATTERY PILL 312 60 models 17449300 COUPL MIC TSYS TM 12 MEASURED 18220700 PROG CABLE R 9022 907 69019 PROG CABLE L...

Страница 12: ...TT DOOR BGE 18093400 18093000 18093300 18093500 18093600 19937700 GRY 18093402 18093002 18093302 18093502 18093602 19937702 BRN 18093404 18093004 18093304 18093504 18093604 19937704 BLK 18093408 18645...

Страница 13: ...using Parts ALLY 60 COLOUR PB HSG TOP HSG BOT BATT DOOR BGE 18093000 18092800 18093100 19937600 GRY 18093002 18092802 18093102 19937602 BRN 18093004 18092804 18093104 19937604 BLK 18645808 18645408 18...

Страница 14: ...OR BGE 18093400 18093000 18093300 18093500 19273300 19273200 LHT GRY 18093401 18093001 18093301 18093501 19273301 19273201 GRY 18093402 18093002 18093302 18093502 19273302 19273202 BRN 18093404 180930...

Страница 15: ...8093301 18093501 18093601 19233801 GRY 18093402 18093002 18093302 18093502 18093632 19233802 BRN 18093404 18093004 18093304 18093504 18093604 19233804 BLK 18093408 18645808 18093308 18646008 18644908...

Страница 16: ...18093301 18093501 18093601 18645001 GRY 18093402 18093002 18093302 18093502 18093602 18645002 BRN 18093404 18093004 18093304 18093504 18093604 18645004 BLK 18093408 18645808 18093308 18646008 18644908...

Страница 17: ...8093000 18092800 18093100 18093200 LHT GRY 18093001 18092801 18093101 18093201 GRY 18093002 18092802 18093102 18093202 BRN 18093004 18092804 18093104 18093204 BLK 18645808 18645408 18644808 18093208 C...

Страница 18: ...301 18093501 18093601 18093701 GRY 18093402 18093002 18093302 18093502 18093602 18093702 BRN 18093404 18093004 18093304 18093504 18093604 18093704 ARCTIC ICE 18093406 18093006 18093306 18093506 180936...

Страница 19: ...00 LHT GRY 18093001 18092801 18093101 18093201 GRY 18093002 18092802 18093102 18093202 BRN 18093004 18092804 18093104 18093204 ARCTIC ICE 18093006 18092806 18093106 18093206 BLK 18645808 18645408 1864...

Страница 20: ...OPEN MDM 19398300 DOME SF OPEN LGE 19398400 DOME SF TULIP STD 19398500 DOME SF PWR SM 19398600 DOME SF PWR MDM 19398700 DOME SF PWR LGE 19398800 Description Part No FITTING KIT THIN TUBE SUREFIT 1944...

Страница 21: ...UBE 2 1B L BLSTR 18629800 THIN TUBE 2 2A L BLSTR 18629900 THIN TUBE 2 2B L BLSTR 18630000 THIN TUBE 2 3A L BLSTR 18630100 THIN TUBE 2 3B L BLSTR 18630200 THIN TUBE 2 1B L BLSTR 18630300 THIN TUBE DOME...

Страница 22: ...val tool Gently lift up bot HSG on the hook end Peel it slowly until it clears off from device Place the assembly with the top HSG at the bottom as shown Press down until the toggle clicks off Place i...

Страница 23: ...ct to issue control when printed Disassemble Procedure Milano 70 is shown Service module with the fixed batt door Locate the pin to separate the batt door from service module and remove it using a pin...

Страница 24: ...weezer Place the side of the ID plate with one prong and insert it Use a finger to press down to make sure both sides are correct in place ID Plate Two prong One prong Push out Replacing the toggle Pr...

Страница 25: ...n 60 models is glued Keep the top HSG inverted with the curve pointing downwards to keep the PB cap from falling off Slowly place the bottom part of the service module by the batt door on top HSG maki...

Страница 26: ...e HI by turning clockwise Mount the new filter as shown Note If the model is a Power or a Power configured to High Gain the filter must NOT be inserted Furthermore for the High Power configuration the...

Страница 27: ...lace module with a new service module from stock Assemble device Restore user settings with Solus Load customer serial no ID Plate using DSA6000 Postponement Procedure Disassemble device Replace parts...

Страница 28: ...g cable Left blue is shown 9022 907 69019 R 9022 907 69029 L P n 17517800 Prog cable ext must be used during final HI test due to current measurement not used with fitting SW Prog adapt clip 17736900...

Страница 29: ...p Slide the clip from adaptor It is important to have the programming cable connected before adding the clip to the programming adaptor Add the clip as shown in the pics The clip is recommended to be...

Страница 30: ...one end of the prog adapt into the square prog port of the device Push the bottom part of prog adapt until it clicks to lock it on the device Connect the CS44 prog cable Button press down to unlock a...

Страница 31: ...ramme execution the IAD calibration will be performed at the appropriate time Another bennefit from the fixture is that the HI is in a well defined position so the telecoil test can be performed witho...

Страница 32: ...able and a batt pill Instead a fresh batt must be inserted The connec tion test is a part of the Final Device Test running on the DSA 6000 The test system will search for a device with a s n matching...