3. Heating control
ü
Under standby mode, you can
set the power level by the corresponding
programming knobs.
In the process of adjusting the power level, clockwise
rotation
can increase the power level from 0 to 15 (maximum), and then rotate
back to “0”
for a cycle; Counter clockwise rotation can be adjusted from 15 to 1
power levels,
and then rotate back to “0” for a cycle.
ü
When the hob is in heating status, press and hold “
” power button for 3s to
switch off,
all the cooking zones stop heating. The indicator light of the previously
heated cooking zone blinks, indicating that the surface of the corresponding
cooking zone is in high temperature state, that is high temperature warning.
ü
When one of the cooking zones needs to stop heating, the cooking zone can be
selected through the corresponding programming knob, turn the programming knob
to adjust the power level to "0" that turns off this cooking zone. At this time, other
cooking zones heating is not affected.
4. Power level adjustment
ü
You can select the appropriate output power level by rotating the programming
knob of the corresponding cooking zone.
ü
The power level is divided into 16 levels, including the shutdown level (0 level). For
the programming knob, rotate clockwise to increase the power level and
anticlockwise
rotation to decrease the power level. When rotating
anticlockwise
, if
the power level is "0" at the beginning, you will rotate the 15 and then decrease the
gear successively.
ü
When the power level of any cooking zone is set to 0, the power output of the zone
will be stopped automatically.
ü
If one of the burners has been heated, and when the power level of all the cooking
zones is 0, the appliance will automatically enter the shutdown status after 1 minute
without effectively programming knob operation.
14
5. Shutdown
ü
Under standby mode or heating mode, press and hold " " button for 3s, the
appliance will go into shutdown mode.
6. Default timing
ü
All the cooking zones have a default timing function. The relationship of
default timing and power level is referred to in the table below
;