1. Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned, and a horizontal
line where the hood base will be.
NOTE: The distance from the horizontal line to an electrical cooktop underneath must be minimum of
600mm & 650mm to the gas cook top and a maximum height of 750mm (refer to table below).
Dimension 1
7
0mm
Dimension 30-
4
65mm
Dimension 1
15
mm
Dimension 1
15
mm
Dimension
242
mm
Di
mension
256
mm
Dimension 8
0
mm
Horizontal line
Hood Base
*If the instructions of the hob specify a greater distance than the minimum above, then that shall be the minimum height for installation
Vertical centre line
Top of hob
/Trivet
Minimum:
Electric 600mm
Gas 650mm
Maximum:
750mm
3x8mm holes for
Hood mount bracket
2x8mm holes for Upper
chimney retaining
bracket
2x8mm holes for Lower
chimney retaining
bracket
Dimension 1
9
0mm
Dimension
128
mm
8