Installing Your Cooker
52
Commissioning 600 size appliances (Stoves 600G & Belling XOU60G)
Pressure test point
Use the oven burner. From inside the oven remove the burner cowl. Remove the small
screw at the LHS of the burner cradle. Slide the burner to the left to access the injector.
Connect a suitable T-piece (incorporating a 1.25mm injector) to the injector. Connect
manometer to the T-piece and turn the oven control to full on to check pressure.
Replace in reverse order.
Burner aeration
All burners have fixed aeration and no adjustment is possible.
Pressure setting
Cat I
2H
G20 Natural Gas @ 20 mbar
Electrical systems check
In the event of an electrical fault the preliminary electrical system check (earth continuity,
short circuit, polarity and resistance to earth) must be carried out.
Ignition
The automatic ignition continues to spark for a short time after the burner has lit until the
flame is established.
Oven
1. Push in and turn the control knob to Gas Mark 9. The oven burner/ignition/light/cooling
fan will come on automatically.
2. Adjust to the required setting.
3. The burner may not come on to a full rate unless the oven door is closed.
The oven burner operates at a low rate for up to 60 seconds until the flame supervi-
sion device opens and full gas rate is obtained.
Grill - The door must be open for the grill burner to ignite.
1. Open the door, push in and turn the control knob anticlockwise to the full on setting.
2. Check condition of flame.
3. Close the door and check that the burner flame goes out. The grill burner will re-ignite
when the door is opened again.
When you first turn on the oven or grill you may notice a smell and some smoke which
comes from the protective coating of oil burning off from some of the parts.
Before leaving the installation
Show the customer how to ignite the oven and grill, and give them this handbook. Thank
you.