44
Requirements
4.1
Requirements on the location
• The floor must be sufficiently strong and stable, because of the weight of the
appliance.
• Make sure that you keep the minimum safety distances of the appliance to flammable
and nonflammable materials. Refer to the installation and maintenance manual.
• Make sure the wall can support the weight of an appliance when attached to the wall.
• Situate the appliance in such a way that the concentric flue outlet connection is
precisely in line with the concentric flue pipe to the ceiling or wall.
• If the fire burns in the appliance, make sure that the wall temperatures, and floor
temperatures below and in front of the appliance, cannot be higher than 85 °C .
• Make sure that the room where the appliance is installed is properly ventilated.
4.2
Other requirements
• The gas supply connection is located at the rear of the appliance for an easy
connection to all directions.
• Only use gas piping of at least 1/2" and a shut-off valve to connect the gas supply to
the gas connection of the appliance.
• Make sure that there is a wall socket with earth connection nearby the appliance. The
socket must be accessible at all times. The powercable (+ 0.5 m) is coming from the
rear of the appliance.
• If the wall of floor is made of flammable material, take correct safety measures. Refer
to the installation and maintenance manual.
• If the concentric flue system is installed in a chimney that is used for wood or coal fire,
clean the chimney.
4.3
Requirements on the outlet
4.3.1
Requirements on the roof outlet
Make sure that the outlet is installed at least 0.5 meter from the edge of the roof.
Note:
All the minimum distances are guidelines. Consult your national and local
directives for the exact minimum distances.
Location of any of the items(*)
Minimum distance between the items
and the roof outlet
At the same roof as the outlet
3 m
At a different roof as the outlet
1 m
At a lower positioned wall than the outlet
1 m
At a higher sloping surface than the outlet
3 m
(*) Items:
• A ventilation opening that services an occupied room, a toilet or a bathroom.
• A combustibion air supply, if the supply flows through an occupied room.
• A window that can be opened that services an occupied room, a toilet or a bathroom.
Requirements
Box Gas Panorama 45/45
7
Содержание Smart Bell Panorama 45/45 MF
Страница 1: ...P Preparation manual Box Gas Panorama 45 45 MF Serial number Production date...
Страница 18: ...5 5 2 Dimensions Box Gas Panorama 45 45 with Storage module Technical specification 18 Box Gas Panorama 45 45...
Страница 42: ...Available components for the concentric flue system 4 42 Box Gas Panorama 45 45...
Страница 43: ...Available components for the concentric flue system Box Gas Panorama 45 45 4 43...
Страница 44: ...Y Your Bellfires dealer 001 29 08 2018 347718...