BHT-206L4-MM-1
5-00-00
Export Classification C, ECCN EAR99
SCHEDULED INSPECTIONS
5-37.
300-HOUR OR 12-MONTH INSPECTION
DATA REFERENCE
INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. _____________________
FACILITY: __________________________________________
HELICOPTER S/N: ___________________________________
REGISTRY NO.: _____________________________________
TOTAL TIME:_______________________________________
SIGNATURE:_______________
_________________________
NOTE
This inspection is only applicable when conducting
the 100-hour airframe progressive or 100-hour
airframe periodic inspection program.
BHT-ELEC-SPM
BATTERY
Remove battery and recondition according to the
BHT-ELEC-SPM and manufacturer's service manual. Inspect
vent lines for obstructions or damage. Clean battery mounting
area prior to installing serviceable battery.
7 NOV 2014 Rev. 20