Reviewing the Programs
Press each time to toggle through the 8 on and off settings.
Clearing the Programs
The only way of removing a program (e.g. 2 On to Off is no longer required) is to reset the
time clock using the
Reset
button and reprogramming
On-Off-Auto
Press to toggle through On/Auto/Off modes as indicated by the Timer Status Bar.
On mode
turns the relay On permanently.
Off mode
turns the relay Off permanently.
AUTO mode
keeps the current On or Off state until the next On or Off event as set by the
timers.
Switching from On to Auto will leave the relay On until the next Off period.
Switching from Off to Auto will leave the relay Off until the next On period.
Manual Override
Press to toggle the relay between On and Off which will then continue until the next event.
LED Status Indicators
12V power is indicated by a Green LED with a Power symbol next to it.
A Red LED with ON next to it indicates the switch contact status.
Connections ‘CO’ and
‘NO’ are closed when the LED is on.
Backup Battery
A CR2032 lithium coin cell is used as a backup battery. This battery will be used up by
leaving the time clock unpowered and is easily replaced by prying its holder out using the
screwdriver slots at the rear. Failure symptoms are the display going very dim or blank
when 12V is removed, also the timer may reset back to 2004 during a 12V failure.