Installation of Door Entry Systems

The

is designed to be wall-mounted in a convenient indoor location.

The

, containing the speech unit, is available with either a surface or flush-mounting back

box. Normally this would be mounted on an outside wall near the front door, and if possible in a sheltered

location.

The

is designed for use on an inward opening door fitted with a surface

night-latch type lock. This should be installed with a small amount of play on the door as operation will be

impaired if too tight.

This is used in conjunction with a time-clock to allow tradesmen access

during restricted hours.

For optimum speech clarity, it is strongly recommended that this system is installed

using twisted-pair telephone cable (eg type CW1308). Use one of the pairs for the R & O connections

between the speech unit and the telephone.

Connect all items by following the diagram overleaf. It is strongly recommended that a single

telephone be connected at a time and fully tested before proceeding to the next.

The speech unit has two controls at the rear for adjustment of speech levels:

Volume A:

Speech level at the Entrance Panel

Volume B:

Speech level at the Telephone

If feedback is experienced (a howl or whistle) turn both controls to 'off' and then slowly adjust each up in turn

until a satisfactory level of speech is attained.

No speech/ insufficient speech: Initially establish correct operation of the Speech Unit by

disconnecting all telephones and re-connecting a single telephone with a short length of cable (R O T only);

Reconnect the telephones one at a time until the fault re-appears. Note: speech will be impaired if one or

more telephones are left off the hook.

Door Entry Telephone

Entrance panel

Model 203 Electric Lock Release

Tradesman button (optional):

Cable requirements:

Installation:

Speech adjustment:

Troubleshooting:

Important Safety Information

The

must be placed in a protected indoor environment such as an

electrical cupboard, close to a 240V AC electrical supply and located no further than 50

metres from the entrance panel. It must be wall-mounted onto plasterboard, wood or a

similar non-conductive material.

Connections to the 240V AC mains supply must be carried out by a qualified electrician or

similar competent person, and made in accordance with accepted safety practices. A two-

pole switch ( as provided by a Consumer Unit or Switch-Fuse) must be included to isolate

both Live and Neutral during Installation or Maintenance . The transformer is protected by

fuses; always replace these with the correct type and rating.

Use only mains cable to BS6004 or equivalent, within the following specified limits:

Power Supply Unit

Conductor Diameter:

Cable Diameter:

Min. 1.0mm (0.8mm )

2

Min. 4.0mm

Max. 2.25mm (4mm )

2

Max. 8.0mm