background image

�� 

.... 

Ofii!57A 

KEY  IN FIRST  IIIODULE; 

....  TI�O  LEADS  FROM  K£Y  PLUG 

AND 

......,.IHQ 

OOAO 

BINOE:R  G�P  IBL-W) 

0!20C  OR 

D200F 

MOUNTING 

CORD 

� 

A75A  OR  A!OOO 

CONNECTO'l 

CA81.£  -------;. 

., 

10 

CD 

..... 

Mil(  INSULATED  AND 

STORED  AS SHOWN, 

WITH  s•M  Oft 

&578  KEY 

IN  FI RST  MODULE; 

(IA-11:1 

LUO 

MUST 

8E 

REMOVED  FROM 

A-H 

OF 

TBl,  INSULATED 

AND 

STORED. 

WfTH  "'"OR 

6"A 

KEY  IN  FIRST  NODULE; 

ITJIAP  A-H 

OF  781  TO  TERMINAL  G ON  NETWORK. 

C0NN£CT 

(Y-O)  AND 

BR-BK)  LEADS 

FROM 

KEY 

PLUG 

TO  A-H  OF 

TBI. 

TO 

E

XTE

N

D  HOLD  LAMP  LEADS  CONNECT  IS-VI 

AND 

(V-Sl 

KEY 

PLUG  LEADS  TO  {G-Y) 

liMO 

(Y-Gl  MOUNTING  CORDS  LEADS 

ll(lf'f:CTIV[LY  USING  SPARE  TERMINALS 

OR 

D-111418' 

CONNECTORS. 

I.  FOR 

USE 

WITH 

l

KEY  SYSTEM  ONLY,  MOVE 

A

(0-Y) 

STRAP  FROM 

18 

TO  SG ON 

TSlll 

MO  IUJ([ 

CONVERSION  SHOWN  IN  TABLE  A. 

•J.  P'IDft 

AOD-ON  COHFERENCE  CONTROL  IN 

THE 

i1A  UY  TELEPHONE 

SYSTEM,  CONNECT 

(BR-Y) 

MOUNTINI 

CORD  LEAD 

(0-W  BINDER  GROUP) 

10 

Tlllt-1'8, 

AlSO 

AUIOVE  COMMON  LEAD 

Of' 

1100-0N 

CONFERENCE  BUTTON  ( CONVERTED  TO 

II .. A.LING)  FAOM  A-H  TERMINAL  AND  CONNECT 

TO 

f>i. 

THE 

•11A  KfY  ¥A.Y  ALSO 

BE 

USED  IN  A 

IIM4LAII  IIIAHNER.ALSO 

SE£  NOTE 

4.  WMt:llf 'lHE  .17A  KEY 

I S  

AEOUIAEO 

AS 

IK.W..-"-"""'SE 

KEY

, THE 

BRASS  STRAP  BETWEEN 

TN[ 

II 

AND  S6 

7ERMINA.LS  OF  THE  KEY  MAY 

8£ 

M;IIOY(O. 

USl  M

I

CORD  OR EQUIVALENT  TO 

co.ECT 

Sl 

TERM 

I MAL  Of 

617A 

KEY  TO A 

01-lfll.Afl  6M>UND 

OR 

NONG ROUNOEO  CIRCUIT. 

a.  WMD1 

I!IIIS1ALliNi  P.....900033 

PRINTED  WIRING 

MAllO 

ASS

E

M

B

LY 

1'0 

PROVIDE  STATION  BUSY 

LAMP 

RATVIIE  IN 

I

A

I  OR 

IA2 

KTS  CONNECT 

A  OR N 

LEAD 

(6-VI  I'"ROM 

LAST 

MODULE  TO 

1Wtt111UL  ll  Of 

TBliii. 

....... 1QMDITOMD 

�--

617A K(Y 

2ND  MODULE 

(636-TYPE  SETS) 

4TH 

MODULE 

ts:n-l'fPE 

SETS! 

CONNECTS  TO 

TBE-SG 

598A  OR 6S6A 

KEY 

2ND  MODULE  1636-TYPE  SETS} 

2ND,  3RD 

OR 4TH 

MODULE 

(637-TTPE 

SETS 

"' 

P

IO<

U

OR  SIG 

"' 

L

:�� 

2ND  PI CKUP 

OR SIG  KEY 

3R0  PICKUP 

OR  SIG KEY 

SRD 

'" 

L

A

M

4TH 

PICKUP 

OR 

SIG  KEY 

LAMP 

STH 

PI

CK

UP 

OR  SIG �EY 

10 

"" 

"' 

LAMP 

6TH  PICKUP 

0A 

SIG KEY 

:i� 

LAMP 

KEY  PLUG 

:�-

DI20C 

D,IDOR  Ill 

'""" 

0 200F 

Ill 

(0-W 

BINDER) 

I" 

IO 

WI 

1

0

-

Y

10-VI 

TO 

S

IV-GI 

0200F 

PLUG2 

CONN  2 

A75.A 

AIOOD 

ONlY 

CORD 

(012

0 C J  

I A75.AI 

(0-W BINDER) 

(O-W  t.M) 

C.-W 

ONU 

PLUG 

CONN 

ll.!OOO 

LE

���:�

� 

tG-W 

2,3  OR 

2,3  OR 

(BR·W  BINDER 

BA

RN

(D200F) 

{

A

I

0

00) 

LEAD 

OESIG 

8\�[R$1 

IW-BLJ  I 

(W-BL 

lW-0) 

IG-WI 

IG-W) 

IBR-W) 

IBR-W) 

(W-8 

IS-WI 

(W

-

S

(W-

S

A,H,SORS\ 

IB

L-R

IBL-RI 

I

R

-

0

I

R

-

01 

IR-GI 

(R-GJ 

IBR-Rl 

IBR-RI 

t

S

-RI 

15-fl) 

I BL-BK) 

IBL-BK} 

IBK-BLJI 

I B

K

-

B

L

A,H,S  OR 

$1 

A

,H

, S ORS

10-BKI 

10-BKI 

I BK-0 

I B�-o 

IG-BKI 

IBK-GI 

S8 

(BK-G) 

IB

R

-

BI<

IBR-BKl 

(BK-BRJI 

tBK-BRl 

IS-BKl 

!S-BKI 

!Y-BL) 

(

Y

-BL) 

IY-0) 

A,H  S 

OR  $1 

\Y-Gl 

!Y-GI 

Pal NOTE 

ll 

(

Y

-B

RI 

IS-Y) 

I< 

20 

(Y-Sl 

_____,... 

21 

IB�-v I 

(1(-BLI 

-----H22 

(0-V) 

•VACANT 

----t--7 

23 

A75AONLTIUNUSEDJ 

-----H<B 

VACANT 

IN 

AIDOO 

\BR-VI 

\V-BR) 

IS  VI 

-----450 

Fig.  4--Module  Arrangements  ond  Cord  and  Cable  Connections  for  Sets  Equipped  with  Even-Count  Color-Code 

Cords  ( Sheet  2  of  3) 

BSP 

502-610-410-i02_1972-Q4-Q7.jpg  Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado  Feb 04,2012  14:14:56 

TO  KEY 

TELEPHONE 

SYSTEMS 

IA,IAI,IA2 

AND 

6A 

Содержание 636A

Страница 1: ... These 636 and 637 type MD rotary dial telephone sets are equipped with 517A jacks for the plugs of a G3L handset or a head telephone set The internal wiring is arranged to electrically connect either the line switch or the headset jacks to the line 2 03 Replacement or substitution of the key in the first module may require wiring changes as shown in the notes for Fig 3 and 4 Some spade tipped con...

Страница 2: ...onvert a key position from pickup locking to signal nonlocking remove the Page 2 screw detail P 10E837 entirely from plunger at the key position to be converted Make the necessary wiring changes as shown in Table B 2 08 A 657B or 599B key turnbutton may be used in the first module for cutoff control of ringer or line Refer to Note 1 Fig 4 and 5 and Table C for necessary wiring changes 3 MAINTENANC...

Страница 3: ...R SHOWN TIA RINGER HAS SINGLE COIL 5200 OHMS AND ONLY R AND BKI LEADS LEG END CURRENT COLOR CODE I MD COLOR CODE INSULATED AND STORED t TERM ON NETWORK J UNDESIGNATED TERM TERM ON 241 TYPE AMPL ARE ON TERM BOARD ON i DIAL OFT NORMAL CONTACTS DP DIAL PULSE CONTACTS LS Ll NE swITCH HS A 517A HEADSET JACK A HS B 517A HEADSET JACK B FL FLA S H KEY LINE SWITCH OFF HOOK S EQUENCE de CLOSES cb CLOSES fg ...

Страница 4: ...1 G R 2211A INO II I 2 3 4 151D ANPLIFIER S Y L Y 11 I f KS 14337 _ CAP R S R f g BK S 8K II S R LS Rj 8L R R Gj I 8L Y 0 G 8R 11 G 8K S 8R R y R HEAD flTELEPHONE SET TRMTR II G Y BL w 21 5 f KS 14337 _ CAP II G Y 8K J 6 R G S 11 A 11 0 R 8K Gt 10 W S HSIAl 0 8K I8L IIl T 2 3 IBR S G LS Y s w G OR 8L 3 8K BL G W c 5 v s1 KS 13490 L1 DP RESISTOR AI 0 V Y 8K G D W E TO FIG 8L Y 8R Y 8K 0L21 8L rl IY...

Страница 5: ...B W ON R S R LS BK S BK W S R R G 6 n 2 2 R IND G BK R BK G R Y W lKS 14337 TO rIG 4 OR 5 f Q A w o R BK AI 0 V Y BL Y BR Y BK V BL G BL V R R OR Rl S Y Y BL B OR 81 Y S Y 11 Rl BL R BR W I S BR BK HEAD BL Y TELEPHONE R SET TRMTR IBL IO Wl 9 HS A 0 BK BL W TIBR S G 2 3 LS Y c r S 0L2t W BL G BL 6 R S R AI 0 7 BK IS I 0 f VVY DIB RINGER S W 5 c d BL W O R FL G OR BL RR I OP BL T 4 S BK G S Y rCAP W...

Страница 6: ... W G r c 0 BA Wl IW BA I IS WI tW Sl 111 AI A7 5A OA AIOOO BL W I I I IW 8LI 0 W I IW O J IG WI I BA Wl tW BAI 5 IS WO 0 IW SJ 6 8l 10 Al I I 10 111 0 P B 0 lR 0 IR GJ 8R R _ ll IR S 10 1 81 8Kl tBK BLI 10 I G 8K 18K G BR BKI It O IG It 1tJI GI 8JI Itl I I S R I IR S 81 IK 18K BL 10 BKI I tG 81 1 BK GI t8R 8K A7 5A AHD AIOOO BL YI BINOEA LE400UIG li A H S Of Sl I A H S ORSI Oft II __ IA IAI IAI A ...

Страница 7: ... SETS CONNECTS TO TBE SG 598A OR6S6A KEY 2ND MODULE 1636 TYPE SETS 2ND 3RD OR 4TH MODULE 637 TTPE SETS I PIO UP OR SIG L 2ND PI CKUP OR SIG KEY 3R0 PICKUP OR SIG KEY SRD LAMP 4TH PICKUP OR SIG KEY 8 LAMP STH PI CKUP OR SIG EY 10 LAMP 6TH PICKUP 0A SIGKEY i LAMP KEY PLUG DI20C D IDOR Ill 0 200F Ill CO RD S It 0 W BINDER I t IO WI m IY 01 _ 10 Y G 10 VI 1 TO SH 3 IV GI 0200F PLUG2 CONN 2 A75 A AIOOD...

Страница 8: ...AMP 4TH ICI UP 0111 SIG k Y LAMP UH PtCKIJf OR SIS KI Y LAMP 6TH PICKUP OR SIG II Y LAMP KEY PLUG m OR Y FROM 0120C CORf G W BINOERl 0200F CORD 5 W BINDER PLUG3 1Dt20C PLUG5 0200F A75A CONN5 AICOD IBL WI A75A IG W A b f_RI 15 W BINOERI LEo O OEStG ATSA ONLY UNUS 01 VACANT IN 11 1000 Fig 4 Module Arrangements and Cord and Cable Connections for Sets Equipped with Even Count Color Code Cords Sheet 3 ...

Страница 9: ...6 Note4 I VI I I II III IV V Note4 Note4 Note 5 Indicates lead i s spade tipped insulate and store t BR S G line switch lead connects to terminal 5 of telephone set terminal board terminal G of network for MD color code when station busy circuit is not provided and to terminal 9 of telephone set terminal board when station busy lamp circuit P 90D033 printed wiring board assembly is provided lAl or...

Страница 10: ...ADD ON CONFERENCE CONTROL IN THE 6A KEY TELEPHONE SYSTEM CONNECT G 11 MOUNTING CORD LEAD RED BINDER GROUP TO TBVI PB ALSO REMOVE COMMON LEAD OF ADO ON CONFERENCE BUTTON CONVERTED TO SIGNALING FROM A H TERMINAL AND CONNECT TO PB THE 617A KEY MAY ALSO BE USED IN A SIMILAR MANNER ALSO SEE NOTE 4 4 IIHEN THE 617A KEY IS REQUIRED AS A DUAL PURPOSE KEY THE BRASS STRAP BETIIEEN THE 51 AND SG TERMINALS OF...

Страница 11: ... BR W W BR 0 BK BK 0 S W W S BL R R BL G BK BK G I I f j 0 R o _ R G SR 61 I I I BR R To _ R S S BK _ I l i 1 BL BI I T CONN I A75A OR 000 BL W B I NDER W BL 0 W W 0 G BKI 81 Gl G WI W G BR W W BR BR BKJ BK BR S W IW Sl BL Rl R Bll S 81 0 R R O I R G J IBL Yl BR RJ R BR S Rl R Sl 0 Yl IBL BKJ 0 36 K BL I S BR 0 0 BK 0 BK O BK 37 0 HOLD BR Y 0 BL SL Y BR BK o w Y BL _ o w S BK Y BK 04 Y BL BK W 20 ...

Страница 12: ...K BLI 10 BK BK 0 G Y Y G BR Y Y BR _ Y S I Bl V V BL 0 V V 0 SPARE BZ A H S OR S L IG V A7SA ONLY UNUSEOl V G VACANT IN AlOOA MD BR V AND AlOOO tV BR 5 V V S Fig 5 Module Arrangement and Cord and Cable Connections for Sets Equipped with MD Mounting Cords Sheet 2 of 3 BSP S02 610 410 i02_1972 Q4 12 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorado Feb 04 2012 14 16 46 TO KEY TELEPHONE ...

Страница 13: ...BR 8R o R G R V 32 R 8K 8 R BL 8K 8 BK W R W G 81t 10 G Bt J BL w s I I I 0 0 G 0 0 8K 0 1 o w G w n1 f l Y 6L 1 v w l I 7 2 1 7 ____ __ VACANT __ _ I ____ __ ____ __ ____ _ l TJ3 I I I V BR s v I v s s s 8 8L W G W 8L o w o BL B BIC 8L BR G I G W I W G BR W 1 W BR 0 8 0 B I S W G w s 8L R 1 R 8L G BK BK G I BR I I O R G R 0 G R I R G 8R 8K BK BR I I BR R fE CD R 8R s _ S 81 8K S 8R V V BR I s v I...

Страница 14: ...f more than six five with common signaling are required use module preceding right hand position repeat connection modifications as shown in table 2 All key positions are arranged in the shop as pickup positions To convert to signaling nonlocking remove the screw detail P 10E837 from the plunger at the key position to be converted Make the necessary connection changes as shown in Table B These arr...

Страница 15: ...network Current color code MD color code Notes 6TH R T BL Y Y BL O R 0 G To Ext Sta To Ext Sta To Ext Ringer or Buzzer A Y 0 0 BK ISS 2 SECTION S02 610 410 SPADE TIPPED lEADS OF MOUNTING CORD BL Y Y IIl J l 0 Y Y 0 BR BK O R 0 G 0 BK 5 BR G Ill Insulate and store Insulate and store Insulate and SG SG Store Insulate and Store 3t At Insulate and Note 2 Note 2 Store A c D c Insulate and Cap c Store R...

Страница 16: ...SETS 2 FROM LAST MODULE I I CURRENT COLOR COOE MO COLOR CODE WIRE OR LEAD P 90D033 PRINTED WIRING BOARD HEADSET JACK A LINE SWITCH CHAINING SWITCH LAST MODUL E 24V STORED LOCATION t NETWORK TERMINAL EARLY PRODUCTION SETS ONLY LEGEND H s A HEADSET JACK A LS LINE SWITCH MODI F I CAT ION COLOR REMOVE FROM CONNECT TO YI TBE 9 IBKI 5 OR Gt O TB lll X BL 6 OR L2t IO WI s 5 OR G t TB 9 BRI s G 5 OR G t T...

Страница 17: ... VOLTS FOR 190 MAX TO OPERATE BOTH RELAYS IK SERIES 20 VOLTS FOR 520 MAX TO OPERATE BOTH RELAYS I N SERIES 26 VOLTS FOR 840 WAX TO OPERAT BOTH RELAYS I N SERIES lEAD Y BR DESIGNATION Bl OR LS lOT USED 2 WHEN STATION BUSY LAMP FEATURE IS REQUIRED WITH A SET THAT HAS A 0120C MOUNT ING CORD t IANUFA CTURED PRIOR TO m 68 TH I S C I RCUIT WUST BE USED I I CURRENT COLOR CODE J 1 10 COLOR CODE Fig 7 Busy...

Страница 18: ... CABLE G BK SP TO 430A KTU A TPA 543042 Fig 8 Priority Hold Using 599H Key Page 18 18 Pages 657L MOUNT I NG CORO CONN KEY CABLE 9 f 34 f SUPL HOLD 1 0 Ql A H BK BR 39 BK BR SP TO 35 430A KTU 1 7 f 42 f I I f 36 f 1 2 f 37 f 1 8 f 43 f so f HOLD 49 f 48 A H 23 f HOLD 24 A SUPL HOLD 25 A H TPA 563668 Fig 9 Priority Hold Using 657L Key BSP 502 610 410 i02_1972 04 18 jpg Scanned by frank Harrell Cowbo...

Отзывы: