Stinger® MS+ Getting Started Guide
2-1
2
Installing a Stinger MS+
Before you begin
Verify that you have completed the following tasks:
■
Selected the installation site
■
Unpacked the Stinger unit
■
Gathered the tools and equipment needed for installation
■
Checked the module configuration in the unit
!
Warning
Before installing the Stinger hardware, be sure to read the safety
instructions in the
Edge Access and Broadband Access Safety and Compliance Guide
. See
Appendix C, “Safety-Related Electrical, Physical, and Environmental Information,”
for information specific to your product.
Mounting the unit
Stinger MS+ units are delivered with mounting brackets installed on the chassis.
Three Models can be ordered with brackets for different rack-mounting
requirements.
■
STGRMSP19—for mounting in a 19-inch (48.26cm) equipment rack
■
STGRMSPETSI—for mounting in a a 51.5cm (20.28-inch) European
Telecommunications Standards Institute (ETSI) equipment rack
■
STGRMSP23— for mounting in a a 23-inch (58.42cm) equipment rack
Note
The rack-mount spacing meets IEC 297-2 and ANSI/EIA-RS-310-C standards.