3.3 Operation specifications
Materials of construction
Part
Material
Pump housing
Cast iron (GJL-200)
Stainless steel (AISI 304)
O-rings
EPDM
Bearing
PEEK/AI203)
All plastics, except for bearings
PPE
All other wetted parts
AISI 304 / AISI 316 L / AISI 316Ti stainless steel
Check valve
Noryl
Technical specification
Rated voltage
115 V
Frequency
50/60 Hz
Power consumption
4–60 W
IP protection
IP 44
Insulation class
Class 155 (F)
Maximum system pressure
150 PSI (10 bar)
Maximum ambient temperature
104°F (40°C)
Permitted temperature range of pumped fluid¹
14°F to 203°F (-10°C to +95°C)
Permitted pumping media²
Water — in potable and domestic water
applications
Water/glycol mixtures up to 50% — in chilled water
applications
¹ For domestic hot water applications, the maximum fluid temperature is 185°F
(85°C). For chilled water applications, the fluid must not freeze. To avoid
condensation, the fluid temperature must always be higher than the ambient
temperature.
² Performance of the pump will noticeably change when pumping water/glycol
mixtures with concentrations higher than 20%.
3 Product Description
10
ecocirc
®
19-16 INSTRUCTION MANUAL
Содержание ecocirc 19-16
Страница 1: ...INSTRUCTION MANUAL P2003557 Rev A ecocirc 19 16 ...
Страница 2: ......
Страница 31: ......