OmniGuard
TM
UPS Power Management Software
58
Note:
Above step is must, without which event message in alarm window, will come as
default message of HP, "NO FORMAT DEFINED" under Event Configuration for each
event. By default, HP puts "NO FORMAT DEFINED".
??
HP Openview Configuration for MIB Browser support
??
Use SNMP MIB Browser option, to check MIB Control feature for each device.
Note:
HP Openview, by default is sending the Get Next request, on selected
node/variable in MIB Tree, say ups Input Frequency, you are trying to get the value, it
actually gets next variable in the tree, and hence shows no values returned. Hence it is
recommended to select parent node, and Start Query. If any configuration we find, to
change this default behavior of sending Get Next request to Get Request, it will be
informed to you.
Set the agent SNMP version
Use MSDOS prompt, after Network Node Manager is started. And give below command to
set the ECM Agent SNMP version.
Command:
xnmsnmpconf -setV agent/Port 1
e.g.
xnmsnmpconf -setV 172.5.25.27/161 1
OR
xnmsnmpconf –setV SystemName/161 1
Where 172.5.25.27 is the IP Address of the PC where ECM is installed or it can be
System Name of PC and Port must be 161.
Configure the SNMP Configuration in HP
??
3 Set timeout value: 2 minute (not compulsory, can be any value)
??
Set community to public in both the community fields
??
Retries:
??
Port: No need to set, it takes default 161
See below screen for ref.
Содержание OmniGuard
Страница 26: ...OmniGuardTM UPS Power Management Software 26...
Страница 33: ...OmniGuardTM UPS Power Management Software 33 View Data Log...
Страница 34: ...OmniGuardTM UPS Power Management Software 34 After Ok is selected this view will be displayed as seen below...
Страница 38: ...OmniGuardTM UPS Power Management Software 38 Logging Screen...
Страница 41: ...OmniGuardTM UPS Power Management Software 41 Command Screen...