OmniGuard

TM

 UPS Power Management Software

 

 

4

 

-Pentium Processor 
- 64 MB RAM 
- 10 GB Hard Disk 
 

 

2. 

OmniGuard

T M

 software requires one dedicated RS-232 serial port on your 

server, for communication with the UPS. 

 

2.2 Installing the UPS  

 

Please refer to the Belkin OmniGuard

T M 

Rackmount UPS user manual. 

 

2.2.1 Computer interface connection 

 

Connect the interface cable to a 9-pin computer interface port on the rear side of the UPS. 
Connect the other end of the cable to the server that will be monitoring/controlling the 
UPS. 

 

 

CAUTION!

 

Connect the interface cable from the server to 

the 9-pin communication port on the rear panel of the UPS 
first, before set up the software.  

 

 

 

 

CAUTION!

 

It is an option for the installation of software, 

UPS works fine without the installation of the software.  

 

 

 

 
 
 
 

Содержание OmniGuard

Страница 1: ...OmniGuardTM UPS Power Management Software 1 Version 1 4 20th March 2003 OmniGuardTM UPS Power Management Software User Manual P74265...

Страница 2: ...nection 4 3 0 Installation Procedure for Windows Versions 5 4 0 Starting OmniGuardTM services 11 5 0 Useful Tips 43 6 0 OmniGuardTM Software for Linux and Solaris Installation Procedure 45 7 0 HP Open...

Страница 3: ...emote system through the software upgrade option These are the operations carried out in the host system server where the UPS is connected physically The environment control screen displays the meter...

Страница 4: ...ual 2 2 1 Computer interface connection Connect the interface cable to a 9 pin computer interface port on the rear side of the UPS Connect the other end of the cable to the server that will be monitor...

Страница 5: ...ing with installation Otherwise the installation will not be complete NOTE Please login the OS as administrator to install the OmniGuard TM software The following steps are required to install the Win...

Страница 6: ...ower Management Software 6 After that you will see a Welcome Screen Note Click Cancel to Exit Setup in case a stoppage is required Clicking the Next button will take you to the Software License Agreem...

Страница 7: ...er Management Software 7 Read the license carefully and click on Yes to move to the next step Note By not accepting the license it will take you to Exit Setup Screen to terminate the currently running...

Страница 8: ...l ask you to enter user information as seen below please enter your name company and Serial number and Press Next to proceed Note You may find the serial number on the first page of the Hardware Manua...

Страница 9: ...on with the named program above into a folder under Start Menu Programs Clicking next will start the installation of the software as per specified details You will see a progress bar as show below Ple...

Страница 10: ...OmniGuardTM UPS Power Management Software 10 Please check to ensure you are getting the icons under the Start Menu as below...

Страница 11: ...s are started the device will be capable of being monitored from any remote machine through a web browser Step 1 Select Settings Icon from startup menu that will get you to below screen Change require...

Страница 12: ...OmniGuardTM UPS Power Management Software 12 The following parameters are configured via the above Settings screen Language selection Multilanguage Feature...

Страница 13: ...usr X1186 lib X11 fonts 3 For Solaris Intel 8 copy fonts to usr openwin lib X11 fonts OmniGuardTM software isstructured this way for multi language feature 1 In Windows OS Program Files Web Based Envi...

Страница 14: ...d the system also start other required programs like Apache server You shall see minimized DOS prompts to check that all applications are started Broadcast receiver Sub Manager Apache Web Server NOTE...

Страница 15: ...GuardTM Power Management Software Step 4 When you want to close the OmniGuardTM software you may just click the De launch ECM This feature is available under both the Start Menu and the Tray Icon opti...

Страница 16: ...6 Learning to use OmniGuardTM Software With the successful installation of the software and the startup of all the specified services the browser will open with the host system s IP and the following...

Страница 17: ...Management Software 17 Enter authorized login name and password here to proceed further After that you will see screen below if UPS is connected to the serial port NOTE Both of the default login ID a...

Страница 18: ...e information to support MIB II to define the System Group Network Show the Server network information PPP Configuration Show the Server Dial up information Date Show server date Administrator Set the...

Страница 19: ...message The input voltage Output Voltage Battery charge level Input frequency Output Source Output Load Output power and the battery Temperature are displayed These are information details which are r...

Страница 20: ...OmniGuardTM UPS Power Management Software 20 Identification The UPS identification details like manufacturer model software version and the Identification are displayed below...

Страница 21: ...to restart etc Parameters are displayed with live values from the UPS The meter refresh interval is set in seconds This time shall be set for how frequently a user wants to refresh the UPS meter data...

Страница 22: ...S Power Management Software 22 Log Configuration The data logging interval is specified here in minutes Also the data logging feature can be enabled or disabled with the check box option provided in t...

Страница 23: ...niGuardTM UPS Power Management Software 23 Input Details regarding the Input to the UPS like Input power Disorder counts Number of Input Lines Input Frequency and Input Voltage are displayed here Outp...

Страница 24: ...tput current Output Power and Output Load are displayed here CAUTION Output current power and load value will be visible only when an actual load is connected to UPS input Battery The current battery...

Страница 25: ...OmniGuardTM UPS Power Management Software 25 Alarm The current alarm setting details that are supported by the UPS are displayed here...

Страница 26: ...OmniGuardTM UPS Power Management Software 26...

Страница 27: ...ons provided by the UPS You can control shutdown restart and auto restart and abort shutdown startup With the shutdown and startup functions the interval in which the UPS will shutdown and restart can...

Страница 28: ...n the shutdown and restart time are specified for a day This functionality will work only when an Action is selected as Enabled Once ok is selected the above event is scheduled as per the set date and...

Страница 29: ...edule sets the shutdown and restart time for specific dates This functionality will work only when an Action is selected as Enabled Once OK is pressed the above event is scheduled as per the set date...

Страница 30: ...able and display the values indicated by the UPS CAUTION The very first time you click View Log Graph Status of Connection it will show Failure as default indicating that no connection has been establ...

Страница 31: ...TM UPS Power Management Software 31 After adjusting the axis dates with the left and bottom corner option arrows shown below you will get a graph like the one below Options are highlighted with arrow...

Страница 32: ...nagement Software 32 View Data Log The data from the UPS which is captured and logged is displayed with this menu After clicking ok you will get actual data log as shown below It is shown in two parts...

Страница 33: ...OmniGuardTM UPS Power Management Software 33 View Data Log...

Страница 34: ...OmniGuardTM UPS Power Management Software 34 After Ok is selected this view will be displayed as seen below...

Страница 35: ...an be configured through this option A pager broadcast email can be sent if an alarm has occurred Under the View Event Action option there are many options that can be configured as per the requiremen...

Страница 36: ...OmniGuardTM UPS Power Management Software 36 Pager Screen Options shown with a check are enabled This must be done for certain events to take place such as the paging feature...

Страница 37: ...ment Software 37 Broadcast Screen If the below options are enabled and the client IP Addresses are added using the Settings Screen shown earlier it will send broadcast messages to all clients configur...

Страница 38: ...OmniGuardTM UPS Power Management Software 38 Logging Screen...

Страница 39: ...OmniGuardTM UPS Power Management Software 39 Trap Screen Please specify the IP Addresses of Managers that are receiving traps Trap Enable must be clicked to have traps received by managers...

Страница 40: ...OmniGuardTM UPS Power Management Software 40 Email Screen Email messages will be sent as per configuration when one of the events occurs in the configured event list...

Страница 41: ...OmniGuardTM UPS Power Management Software 41 Command Screen...

Страница 42: ...OmniGuardTM UPS Power Management Software 42 Shutdown OS UPS This option must be enabled to make the shutdown feature active...

Страница 43: ...our DOS prompt process for agent process as below The above screen must detect the UPS on the stated COM Port in order to receive the message UPS Found From here you can also confirm the detection of...

Страница 44: ...nge siz e fonts in screens You can use the smallest font to avoid changes in alignment but that will make the fonts very small and not easily readable by the user 5 For Windows NT 2000 PC On occasion...

Страница 45: ...Serv 1 1 2 tar gz 3 jsdk20 solaris2 sparc tar Z 4 jdk1 2 2 tar gz OmniGuardTM software Linux Releases 1 ECM_XXXXX2003_LINUX tar This is the main release XXXXX Software release date 2 In CD ROM that co...

Страница 46: ...NVIRRONMENT MUST BE THERE LIKE KDE ON HIS LINUX PC 5 InstallLinuxECM To install OmniGuardTM software only whenever there is an update release for any bug fixing and feature enhancement 6 ECM_Install T...

Страница 47: ...commands 1 Install JDK Move JDK file to usr local src Command mv jdk1 2 2 usr local src 2 Install JSDK Move jsdk20 solaris2 sparc_tar Z file to usr local src Commands mv jsdk20 solaris2 sparc_tar Z us...

Страница 48: ...ache bin apachectl start 4 Install JServ Move ApacheJServ 1 1 2 tar file to usr local src Commands mv ApacheJServ 1 1 2 tar usr local src cd usr local src Install JServ to usr local jserv Commands cd...

Страница 49: ...d line ApJServLogFile usr local apache conf jserv mod_jserv log Add line ApJServMount servlets servlets Comment out other entries Edit usr local apache conf jserv jserv properties Add line zones sevle...

Страница 50: ...ver linux22_tar tar file to home directory Command mv apache_1_3_26 i686 whatever linux22_tar tar HOME Run the script Command Linux_install_WUPS Installation on intel solaris with commands 1 Install J...

Страница 51: ...JServ Move ApacheJServ 1 1 2 tar file to usr local src Command mv ApacheJServ 1 1 2 tar usr local src Install JServ to usr local jserv Commands cd usr local src tar xvf ApacheJServ 1 1 2 tar cd Apach...

Страница 52: ...er entries Edit usr local apache conf jserv jserv properties Add line zones sevlets Comment out other entries Addline servlets properties usr local apache conf jserv servlets pr operties Comment out o...

Страница 53: ...home directory Command mv jsdk20 solaris2 sparc_tar Z HOME Move apache_1_3_26 i86pc_sun_solaris2 280 tar gz file to home directory Command mv apache_1_3_26 i86pc_sun_solaris2 280 tar gz HOME Run the s...

Страница 54: ...MIB if already loaded till now Unload it 2 Open Event Configuration screen delete all events under your ups MIB already loaded and then remove Enterprise upsMIB Note 2 All MIB developed for each devi...

Страница 55: ...OmniGuardTM UPS Power Management Software 55 Steps to load MIB 1 Load with the Load Unload Mibs option 2 Open Event Configuration Menu You will see upsMIB Enterprise in the enterprise list...

Страница 56: ...iGuardTM UPS Power Management Software 56 3 Configure each event as follows Select event under upsMIB Enterprise 4 Select event falling under upsMIB Enterprise double click to modify it See screen bel...

Страница 57: ...option as per your convenience This configured format in this option will be used to log your traps in Application Alert Alarms Recommended that you set below line in this option to get proper format...

Страница 58: ...ed Hence it is recommended to select parent node and Start Query If any configuration we find to change this default behavior of sending Get Next request to Get Request it will be informed to you Set...

Страница 59: ...TM UPS Power Management Software 59 Correct selection of parent node as below screen This will get all child variables value in the MIB Values bottom window Set ECM IP Address and community to public...

Страница 60: ...OmniGuardTM UPS Power Management Software 60 Incorrect selection for specific variable watch This is due to default behavior of HP sending Get Next request...

Страница 61: ...guration or hosts file configuration in your PC where HP 6 31 NNM is installed This is specific to HP network configuration problem User is expected to know this as minimum for working with HP Openvie...

Отзывы: