background image

Technical Data

307645

Service

chilled, hot water, up to 60% glycol

Flow Characteristic

equal percentage

Controllable Flow Range

75°

Size [mm]

0.5” [15]

End Fitting

NPT female ends

Body

forged brass

Ball

chrome plated brass

Stem

brass

Seat

Teflon® PTFE

Seat O-ring

EPDM (lubricated)

Diaphragm

EPDM

Body Pressure Rating [psi]

360

Media Temperature Range 

(Water)

36°F to 212°F [2°C to 100°C]

Maximum Allowable Operating 

Temperature

212°F [100°C] *

Media Temperature Limit

250°F [121°C] *

Max Differential Pressure (Water) 40 psi
Close-Off Pressure

75 psi

Cv

1.4 

Weight

0.2 lb [0.1 kg]

Leakage

0%

Servicing

maintenance free

* If temperature exceeds 212°F operating range due to a boiler control failure the valve will safely contain 

the hot water but manufacturers product warranty becomes invalid. Valve and actuator replacement is at 

the expense of others.

Application

The QCV zone valves are suited for large commercial buildings where higher 

close-off and the ability to change flow is desired. Common applications include 

unit ventilators, fan coil units, VAV reheat coils, fin tube casing, radiant panels 

and duct coils. The valve fits in space restricted areas and can be assembled 

without the use of tools.

Suitable Actuators

 

Non-Spring

Electronic Fail-Safe

Z2050Q-F

CQ

CQK

Dimensions (Inches [mm])

E

F

D

C

B

A

A

B

C

D

E

F

4.5” [114] 2.05” [52] 3.27” [83] 2.71” [69]

0.94” 

[23.88]

0.94” [24]

Z2050Q-F, 1/2”, ZoneTight Valve

800-543-9038

 USA

866-805-7089

 CANADA

203-791-8396

 LATIN AMERICA / CARIBBEAN

Date created, 03/20/2017 - Subject to change. © Belimo Air

controls (USA), Inc.

Содержание ZoneTight Z2050Q-F

Страница 1: ...ontrol failure the valve will safely contain the hot water but manufacturers product warranty becomes invalid Valve and actuator replacement is at the expense of others Application The QCV zone valves are suited for large commercial buildings where higher close off and the ability to change flow is desired Common applications include unit ventilators fan coil units VAV reheat coils fin tube casing...

Страница 2: ...C B A A B C D E F 4 5 114 2 05 52 3 14 80 2 56 65 1 02 26 Z2050Q F 1 2 ZoneTight Valve 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN Date created 03 20 2017 Subject to change Belimo Aircontrols USA Inc ...

Страница 3: ...ay before fail safe activates Pre charging Time 5 to 20 seconds Ambient Humidity 5 to 95 RH non condensing Ambient Temperature Range 35 F to 104 F 1 7 C to 40 C Storage Temperature Range 40 F to 176 F 40 C to 80 C Housing IP40 NEMA 2 Housing Material UL94 5VA Agency Listings cULus acc to UL60730 1A 2 14 CAN CSA E60730 1 02 CE acc to 2004 108 EC and 2006 95 EC Noise Level Motor max 35 dB A Servicin...

Страница 4: ... and troubleshooting of this product it may be necessary to work with live electrical components Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury Line Volts Control Si...

Отзывы: