Wiring diagrams

AC/DC 24 V, modulating

Operation on the MP-Bus

Y

U

1

3

2

5

– +

T

~

DC

 

(0)2…10

 

V

DC

 

2…10

 

V

Cable colours:

1 = black 

2 = red 

3 = white 

5 = orange

1

3

2

5

– +

T

~

Y

U

Sensor

MP

Cable colours:

1 = black 

2 = red 

3 = white 

5 = orange

Functions

Functions when operated on MP-Bus

Connection on the MP-Bus

MP-Bus Network topology

1

2

3

5

MP

~

T

U

Y

A)

A) more actuators and sensors

(max.8)

There are no restrictions for the 

network topology (star, ring, tree or 

mixed forms are permitted).

Supply and communication in one 

and the same 3-wire cable 

• no shielding or twisting necessary

• no terminating resistors required

Connection of active sensors

Connection of external switching contact

1

2

3

5

MP

~

T

U

Y

A)

A) more actuators and sensors

(max.8)

• Supply AC/DC 24 V

• Output signal DC 0...10 V

  (max. DC 0...32 V) 

• Resolution 30 mV

1

2

3

5

MP

~

T

U

Y

A)

p

A) more actuators and sensors

(max.8)

• Switching current 16 mA @ 24 V

• Start point of the operating range

must be parameterised on the MP

actuator as ≥ 0.5 V

Connection of passive sensors

1

2

3

5

MP

~

T

U

Y

A)

Ni1000

PT1000

NTC

–28...+98°C

–35...+155°C

–10...+160°C

 1)

850...1600 Ω

 2)

850...1600 Ω

 2)

200 Ω...60 kΩ

 2)

A) more actuators and sensors

(max.8)

1) Depending on the type

2) Resolution 1 Ohm

NV24A-MP-TPC

Globe valve actuator, modulating, communicative, AC/

DC 24 V, 1000 N

Electrical installation

NV24A-MP-TPC • en-gb • 2020-01-22 • subject to changes

4

Содержание ENYE CONTROLS H2 S Series

Страница 1: ...of glycol 0 C 130 C 2500kPa PN25 Control path A AB equal percentage to VDI VDE 2173 n gl 3 optimised in the opening range 100 1 Max 0 01 of kvs value DIN EN 1 49 and DIN EN 605 4 4 Internal thread to...

Страница 2: ...profiling the valve cone On the NV or SV linear actuator the valve stem can be actuated manually using a hexagonal key Mode of operation Flow characteristic Manual operation Recommended mounting posi...

Страница 3: ...DN mm L1 mm H1 mm L3 mm X mm Y mm Weight kg 29 28 4 5 35 43 56 5 296 299 303 306 311 318 9 39 43 52 5 60 68 100 100 100 100 100 100 1 1 2 1 6 2 2 5 8 1 Minimum distance with respect to the valve cent...

Страница 4: ...on feedback U 2 10 V Position feedback U note Max 0 5 mA Position feedback U variable Start point 0 5 8 V End point 2 5 10 V Position accuracy 5 Manual override with push button can be locked Stroke 2...

Страница 5: ...ctuator is connected with a standard modulating signal of 0 10 V and drives to the position defined by the positioning signal The measuring voltage U serves for the electrical display of the actuator...

Страница 6: ...ion is in the home position 0 The actuator then moves into the position defined by the positioning signal A range of settings can be adapted using the PC Tool see MFT P documentation Accessories Descr...

Страница 7: ...minating resistors required Connection of active sensors Connection of external switching contact 1 2 3 5 MP T U Y A A more actuators and sensors max 8 Supply AC DC 24 V Output signal DC 0 10 V max DC...

Страница 8: ...ntrol with 4 20 mA via external resistor 1 3 2 5 T 1 3 2 5 Y U DC 0 2 10 V DC 2 10 V Y U Y U U 1 3 2 5 4 20 mA DC 2 10 V 500 U Y T Caution The operating range must be set to DC 2 10 V The 500 resistor...

Страница 9: ...5 Y U a b c Close 1 MIN ZS MAX d e Open Y T e g 1N 4007 1 2 3 5 Y U Close 1 MIN ZS MAX Open Y DC 0 10 V 1 Caution This function is only guaranteed if the start point of the operating range is defined...

Страница 10: ...ngages motor stops manual override possible Gear engages standard mode 5 Service plug For connecting parameterisation and service tools 10 Manual override Clockwise Counterclockwise Actuator spindle e...

Страница 11: ...globe valves Data sheets for globe valves Notes for project planning 2 way and 3 way globe valves General notes for project planning Tool connections Introduction to MP Bus Technology Overview MP Coop...

Отзывы: