Belden Hirschmann PC150/36V/48V-IP67 Скачать руководство пользователя страница 5

5

EMC: emitted interference - line related / Power Port DC

EN50155

Class A

0.15 MHz to 0.5 MHz, max. 99 dB

(µV)/m, quasi-peak

0.5 MHz to 30 MHz, max. 93 dB 

(µV)/m, quasi-peak

EMC: interference immunity- radiated

IEC/EN61000-4-3

Electromagnetic field

80 to 2700 MHz

20 V/m

EMC: interference immunity- line related

IEC/EN61000-4-2

Electrostatic discharge

Contact discharge

6 kV

Air discharge

8 kV

IEC/EN61000-4-4

Fast transients (burst)

Power 

input

4 kV

IEC/EN61000-4-5

Voltage surges

Power input

1 kV line / line

Power input

2 kV line/earth

IEC/EN61000-4-6

Line-conducted interference voltages

150 kHz to 80 MHz

10 V

Mechanical components

Dimensions - without cables (W x H x L)

115 mm x 65 mm x 240 mm

Weight

3,100 g

Housing material

Aluminum, UL94-V0

Casting compound

Polyurethane

Vibration resistance

IEC60068-2-6 Test Fc

Test level according to IEC61131-2

EN61373, category 1

Class A (broadband noise), installation according to EN50155

Shock resistance

IEC60068-2-27 Test Ea

Test level according to IEC61131-2

EN61373, category 1

Class A (broadband noise), installation according to EN50155

Scope of delivery

Power supply unit incl. ferrite on secondary cable, startup instructions and dispatch note for returning product

Отзывы: