![Belden Hirschmann PC150/36V/48V-IP67 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/belden/hirschmann-pc150-36v-48v-ip67/hirschmann-pc150-36v-48v-ip67_description-and-operating-instructions_2725622004.webp)
4
4. Technical data
Input PC150/36V/48V-IP67
Rated voltage range
24 V DC to 48 V DC
Rated input current
8.0 A DC to 3.8 A DC
Power failure bridging
min. 10 ms across entire voltage range
Polarity reversal protection
Yes, via longitudinal diode
Fuse (exchangeable)
16 A (T)
Connection type
Lapp Cable Olflex 150,
Cable cross-section 2 x 2.5
mm
2
2 x terminal sleeve
Input PC150/72V/48V-IP67
Rated voltage range
72 V DC to 110 V DC
Rated input current
2.4 A DC to 1.5 A DC
Power failure bridging
min. 10 ms across entire voltage range
Polarity reversal protection
Yes, via longitudinal diode
Fuse (exchangeable)
6,3 A (T)
Connection type
Lapp Cable Olflex 150,
Cable cross-section 2 x 2.5
mm
2
2 x terminal sleeve
Efficiency
PC150/36V/48V-IP67
> 80%
PC150/72V/48V-IP67
> 80%
Output
Output voltage
48 V DC (0 to +2% accuracy), safety low voltage (SELV) EN 60950-1
Output current (max.)
3,2 A
Connection type
Lumberg Automation RKT 5-228
5-pin, cable cross-section 5 x 0.5
mm
2
Safety
Standards
IEC/EN60950-1, IEC/EN61131-2:2007
Class of protection
Class I equipment
Enclosure type
IP 67
Insulation resistance
Primary secondary: 2000 V AC
Primary housing: 1000 V AC
Secondary housing: 1500 V AC
Insulation resistance
> 500 Megaohm
Approvals
Standards
IEC/EN 60950-1:2006
VDE certification: pending
IEC/EN61131-2:2007
CE Declaration –
programmable logic controllers
EN50155 Class S1 C2
Railway applications electronic systems in
railway vehicles (environmental requirements)
Operating Conditions
Operating temperature
-40 to +70 °C
permanently
-40 to +85 °C
for max. 10 minutes
Storage temperature
-55 to +85 °C
Protection and monitoring
Current limitation
Yes, permanent short-circuit protection
High voltage test
Routine testing in series
EMC: emitted interference - radiated
EN50022
Class A
30 MHz to 230 MHz, max. 40 dB
(µV)/m quasi-peak, 10 m distance
230 MHz to 1000 MHz, max. 47 dB
(µV)/m quasi-peak, 10 m distance
1000 MHz to 2000 MHz, max. 56 dB
(µV)/m, average, 3 m distance
FCC47 CFR Part 15
Class A
30 MHz to 88 MHz, max. 39 dB
(µV)/m, quasi-peak, 10 m distance
88 MHz to 216 MHz, max. 43.5 dB
(µV)/m, quasi-peak, 10 m distance
216 MHz to 960 MHz, max. 46.5 dB
(µV)/m, quasi-peak, 10 m distance
960 MHz to 2,000 MHz, max. 49.5 dB
(µV)/m, quasi-peak, 10 m distance