Common Configuration Panels to all XIP-3901 Applications
INSTALLATION AND OPERATION GUIDE
XIP-3901 | 143
one Critical or Major alarm is triggered, the LED will change to red. If no Critical or no Major alarms are triggered
and Minor alarms are occurring, the LED will change to yellow.
Overall Alarm
This column is used to set the severity level of each individual alarm to the Overall Alarm associated with the card.
The Overall Alarm is shown in the upper left corner of the iControl panel and also appears at the bottom of the
Status/Name column.
GSM Contribution
This column is used to set the severity level of each individual alarm to the GSM Alarm Status associated with this
card. GSM is a dynamic register of all iControl system alarms and is also an alarm provider for external applications.
The possible values for this contribution are related to the Overall Alarm contribution:
If the Overall Alarm contribution is Disabled, the GSM alarm contribution can be set to any available value.
If the Overall Alarm contribution is any level other than Disabled, the GSM contribution is forced to follow the
Overall Alarm.
Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for troubleshooting and
identifying event sequences. Check the box to log alarm events for each individual alarm.
Levels associated with these alarms:
The pulldown menus may contain some or all of the following settings:
The alarm makes no contribution (black icon)
The alarm is of minor importance (yellow icon)
The alarm is of major importance (orange icon)
The alarm is of critical importance (red icon)
The alarm exists but has no effect (used for text and composite alarms)
Note:
As a shortcut, you can click one of the Set All boxes beside a section heading to open a pulldown menu
that lets you assign a level to all alarms in that section of the column simultaneously.
Once the alarms are configured, you may accept the changes or discard them:
Overall alarm and GSM contribution follow card LED
Check the box to force the Overall Alarm and GSM
contribution to match the Card LED status.
All Overall Alarms and GSM contributions for which
there is a Card LED alarm will be forced to match the
Card LED alarm.
All Overall Alarms and GSM contributions for which
there is no Card LED alarm will be forced to be
Disabled.
A warning dialog box will open to ask you to confirm the
action, since it will change the configuration and cannot be
undone.
Figure 94
Warning for Follow LED Change