Remote Contact Activation: .......................... ≤1Vdc
(typically grounded through GPI contacts,
TTL/HCMOS level drive also suitable)
Input Resistance when pulled
to ground (GPI output activated): .............. 5kΩ ±1%
Output Contact Pairs (Pins 13&14)
Contact Format: ................................................ 1 Form A (non-activated condition)
Contact Resistance: .......................................... 100mΩ
Switching Voltage: ........................................... 125Vac, 110Vdc maximum
Contact Rating: .................................................. 2A @ 30Vdc,
0.3A @ 125Vac (resistive load)
Maximum Toggle Rate: ................................... ≈5Hz
Breakdown Voltage:
Between Open Contacts: ......................... 750Vrms for 1minute
Between Contact and Coil: ...................... 1500Vrms for 1 minute
Format Bias Output (Pin 10 on the DB-26 HD Data I/O connector):
Output Voltage: ................................................. 5Vdc ±5%
Output Current Limit: ...................................... 300mAdc maximum
Note: Aside from providing a bias voltage for the data format options, the “Format Bias”
pin also provides a DC voltage source for low power loads that may be switched by the
GPI output contacts, such as LED’s for Tally use etc.
Electro-Optical
Operating Wavelength:
Standard ............................................................... 1300 nm
Others available ................................................. CWDM wavelength 1270-1660nm
TX Laser output power .................................... -6 dBm
RX Sensitivity:
270MB/s ................................................................ -24 dBm
1.5 Gb/s ................................................................. -22 dBm
3.0 Gb/s ................................................................. -20 dBm
Fiber Compatibility................................................. Single Mode only
Distance Limitations: (1.5Gb/s) .......................... 16 db optical loss (30 km, nominal*)
Optical Connector Options: ................................ ST, MX, OpticalCON, SMPTE 304M
* The maximum cable length varies due to optical loss that can depend on cable quality,