Belden GRASS VALLEY HDA-1941 Скачать руководство пользователя страница 1

 

 

 
 
 
 
 
 

 

 

 
 
 
 

HDA-1941/-1951 

HDA-3941/-3951 

Single/Dual 3G/HD/SD SDI Distribution Amplifiers 

 

 

 

 

 

 

 

 

 

Guide to Installation and Operation 

 

M3058-9900-101 
 

2016-02-12 

 

  

Содержание GRASS VALLEY HDA-1941

Страница 1: ...HDA 1941 1951 HDA 3941 3951 Single Dual 3G HD SD SDI Distribution Amplifiers Guide to Installation and Operation M3058 9900 101 2016 02 12 ...

Страница 2: ...e with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This equipment has been tested and found to comply with the requirements of the EMC directive 2004 108 CE EN 55022 Class A radiated and co...

Страница 3: ... 2 Installing the HDA Card 4 2 3 Rear Connector Panels 5 2 4 Bypass Relay 8 3 Operation 9 3 1 Control Options 9 3 2 Card Edge Status LED 9 3 3 Local control using the Densité frame control panel 10 3 4 Remote control using iControl 11 3 4 1 The iControl graphic interface window 11 3 4 2 The Status panel 13 3 4 3 The Input panel 13 3 4 4 The Alarms panel 14 3 4 5 The Info panel 16 4 Specifications ...

Страница 4: ...GUIDE TO INSTALLATION AND OPERATION HDA 1941 51 HDA 3941 51 ...

Страница 5: ...at 1 5 Gb s and up to 100 meters 328 feet at 3 Gb s Critical applications protection is provided by bypass relays available on selected rears Note HDA 1941 and HDA 1951 are Densité 2 series cards HDA 3941 and HDA 3951 are Densité 3 series cards Apart from the size difference they are functionally identical Function Densité 2 Densité 3 Single DA HDA 1941 HDA 3941 These two cards are functionally id...

Страница 6: ...GUIDE TO INSTALLATION AND OPERATION 2 HDA 1941 51 HDA 3941 51 1 3 Block Diagrams Figure 1 1 a HDA 1941 3941 Functional Block Diagram Figure 1 1 b HDA 1951 3951 Functional Block Diagram ...

Страница 7: ... HDA 3941 51 3 1 4 Front Card edge Interface The front card edge of the HDA incorporates two elements Status LED see section 3 2 Select Button see section 3 3 Figure 1 2 Front card edge layout Select Button IRD 3802 Status LED Status Select HDA 1941 ...

Страница 8: ... panels can be installed with the frame power on The card has connectors which plug into a mid frame mother board for distribution of power and for connection to the controller card and a second connector which plugs directly into the rear connector panel for input and output The rear connector panel must be installed with the card out of the frame To install the connector panel 1 If a card is ins...

Страница 9: ... the on card status LED flashing red to indicate that there is no connection to the rear panel 3 Close the front door of the frame 2 3 Rear Connector Panels The following diagrams illustrate the layout and connectors on the HDA 1941 1951 3941 and 3951 rear panels Note some of these panels may not be immediately available please check before ordering HDA 1941 Rear Panels HDA 194N SRP Single rear fo...

Страница 10: ...ectors HDA 195N SRP D Single rear for dual 1x4 operating mode with DIN connectors HDA 195N DRP R Double rear for dual 1x4 operating mode with bypass relays and BNC connectors HDA 3941 Rear Panels HDA 394N 3SRP Single rear for 1x7 operating mode with BNC connectors HDA 394N 3SRP RSingle rear for 1x7 operating mode with bypass relay and BNC connectors ...

Страница 11: ...ual 1x5 operating mode with DIN connectors This table summarizes the input output connections on the various rear panels shown above I O Connections Use with Rear panel type 3G HD SD SDI IN 3G HD SD SDI OUT Bypass HDA 1941 HDA 3941 HDA 1951 HDA 3951 HDA 194N SRP 1 4 HDA 194N SRP D 1 9 HDA 194N DRP 1 9 HDA 195N DRP 2 2 x 4 HDA 195N SRP D 2 2 x 4 HDA 195N DRP R 2 2 x 4 2 HDA 394N 3SRP 1 7 HDA 394N 3...

Страница 12: ... OUT serial digital video outputs The HDA provides multiple 3G HD SD SDI video outputs labeled 3G HD SD OUT 1 2 etc The SDI video signal conforms to the SMPTE 424M SMPTE 292M or SMPTE 259M C standard All outputs are DVB ASI compatible 2 4 Bypass Relay Rear panels with an integrated bypass relay or relays are identified by a R designation The relays activate automatically if the card loses power or...

Страница 13: ... visible through the front access door of the DENSITÉ 3 frame This multi color LED indicates the status of the HDA by color and by flashing steady illumination The chart shows how the various error conditions that can be flagged on the HDA affect the LED status If a cell is gray the error condition cannot cause the LED to assume that status If more than one LED status is possible for a particular ...

Страница 14: ...s of text each 16 characters in length and four pushbuttons Assign the panel to operate the HDA by pushing the SELECT button on the front edge of the HDA card The STATUS LED on the HDA flashes yellow The local control panel displays a menu that can be navigated using the four pushbuttons located beside the display The functionality of the pushbuttons is as follows Used for menu navigation and valu...

Страница 15: ...l panels associated with the HDA and their use Please consult the iControl User s Guide for information about setting up and operating iControl Exception At the time of printing the HDA was not supported by iControl Solo In iControl Navigator or iControl Websites double click on the HDA icon to open the control panel 3 4 1 The iControl graphic interface window The basic window structure for the HD...

Страница 16: ...at can appear and how they are to be interpreted In cases where there is more than one possible interpretation read the error message in the iControl window to see which applies Table iControl Status Icon interpretation Icon 1 Manual Card Configuration green Remote card control activated The iControl interface can be used to operate the card yellow Local card control active The card is being contr...

Страница 17: ...shown underlined in the menus found in the Annex to this document beginning on page 20 3 4 2 The Status panel This panel shows the status of the inputs to this HDA For HDA 1941 and HDA 3941 only IN A is shown because there is no IN B Input Status A and B Data rate 270 Mbps 1 5 Gbps 3 Gbps the detected input data rate is indicated by a green status icon No Lock No Signal either of these conditions ...

Страница 18: ...evel of contribution of each individual alarm to the alarm named in the column heading to be set Click on the alarm icon to see the available levels then click on one to select it Card LED This column allows configuration of the contribution of selected individual alarms to the status LED located on the front card edge The Card LED status is shown at the bottom of the alarm tree in the Status Name...

Страница 19: ...f minor importance yellow icon The alarm is of major importance orange icon The alarm is of critical importance red icon The alarm exists but has no effect used for text and composite alarms Shortcut if you click on one of the Set All boxes in the Card LED Overall Alarm or GSM Contribution columns you will open a pulldown that lets you assign a level to all alarms in that section of the column sim...

Страница 20: ... changes and leaves the previous settings intact 3 4 5 The Info panel When the HDA is included in an iControl environment certain information about the card should be available to the iControl system The user can enter labels and comments that will make this card easy to identify in a complex setup This information is entered into data boxes in the Info control panel Label type the label that is s...

Страница 21: ...e lookup services to which this HDA is registered Add Force the iControl service for this HDA to register itself on a user specified Jini lookup service using the following syntax in the Input data box jini ip_address where ip_address is the ip address of the server running the lookup service Remove select one of the services listed in the Joining Locators window by clicking on it and click Remove...

Страница 22: ...Hz to 3GHz ELECTRICAL OUTPUTS up to 10 Signal 3G HD SD SDI SMPTE 424M 292M and 259M C compliant Supports data rates of 270 1483 5 1485 2967 2970Mb s EN50 83 9 DVB ASI 270 Mbps all outputs Return loss 15 dB for up to 1 5GHz 10 dB from 1 5GHz to 3GHz Jitter wideband 0 2 UI p p Rise Fall time Reclocker ON 135 ps 20 to 80 for HD and 3G 400 800 ps 20 to 80 for SD Reclocker OFF 135 ps for all formats 3G...

Страница 23: ...Canada or 1 530 478 4148 To obtain a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Страница 24: ...SIGNAL 270 Mbps 1 5 Gbps 3 Gbps RECLOCKER INPUT A OFF ON CONFIG ALARMS IN A NO LOCK ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI IN A NO SIGNAL ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI NO REAR ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI VERSION CARD V xxx FACTORY DEFAULT RESTORE restore settings to underlined values ...

Страница 25: ...INPUT A OFF ON INPUT B OFF ON CONFIG ALARMS IN A NO LOCK ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI IN A NO SIGNAL ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI IN B NO LOCK ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI IN B NO SIGNAL ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI VERSION CARD V xxx FACTORY DEFAULT RESTORE restore setti...

Отзывы: