![Belanger Signature Series Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/belanger/signature-series/signature-series_owners-manual_2725312080.webp)
INTEGRA® / E-1063
7-2
Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL102
Chapter 7 Faults and Alarms
Faults
Fault Codes
RS-232 must be set to Modem before paging can occur.
No.
Description of Problem
135
Roller up fault and Conveyor Jam
159
Photo Eye fault
183 Conveyor
jam
190 VFD
Fault
207
Roller up fault
208
Pump Water low
217
Hydraulic Tank 2 low
223 Input
fault
238 Overload
tripped
239 GFCI
fault
243 Slow
Net
244
Hydraulic Tank 1 low
245 Low
air
251 E-Stop
255 Normal
operation
Alarm List
All Faults and Alarms will show up on the Alarm List but only Check Enter Photo Eye will signal
an alarm on the screen and require an acknowledgement.
ACCEPT may need to be pressed from the POWERUP CHOICE screen if system is not
operating.
After and E-STOP or RESET, the Slow Comm Sta will change to 000. If a Station Number
appears, the comm. Cables to that station should be reviewed. If the station is not part of the
system, disable it at the HMI.
Содержание Signature Series
Страница 2: ......
Страница 4: ......
Страница 7: ...Chapter 1 Introduction Chapter 1 Introduction Chapter REV 01 ...
Страница 8: ......
Страница 13: ...Chapter 2 General Machine Operations Chapter 2 System Overview Chapter REV 01 ...
Страница 14: ......
Страница 21: ...INTEGRA E 1063 1MANUL102 Belanger Inc 1001 Doheny Ct Northville MI 48167 Ph 248 349 7010 Fax 248 380 9681 2 7 ...
Страница 22: ......
Страница 24: ......
Страница 28: ......
Страница 44: ...INTEGRA E 1063 4 16 Belanger Inc 1001 Doheny Ct Northville MI 48167 Ph 248 349 7010 Fax 248 380 9681 1MANUL102 ...
Страница 45: ...Chapter 5 Operator Interface Programming Chapter 5 Operator Interface Wash Setup Screens Chapter REV 01 ...
Страница 46: ......
Страница 69: ...Chapter 6 Techniques in Programming Chapter 6 Techniques in Wash Setup Chapter REV 01 ...
Страница 70: ......
Страница 76: ......
Страница 77: ...Chapter 7 Faults and Alarms Chapter 7 Faults and Alarms Chapter REV 01 ...
Страница 78: ......
Страница 84: ...INTEGRA E 1063 7 6 Belanger Inc 1001 Doheny Ct Northville MI 48167 Ph 248 349 7010 Fax 248 380 9681 1MANUL102 ...
Страница 85: ...Chapter 8 Network and E Mail Application Chapter 8 Network and E Mail Application Chapter REV 01 ...
Страница 86: ......
Страница 91: ...Chapter 9 E 1063 Screen Map Chapter 9 E 1063 Programming Screen Map Chapter REV 01 ...
Страница 92: ......
Страница 93: ......