Bel Canto e.One Phono Скачать руководство пользователя страница 3

The Lightning Flash with arrowhead symbol within 
an equilateral triangle is intended to alert the user to 
the presence of uninsulated "dangerous voltage" 
within the product enclosure that may be of sufficient 
magnitude

 

to constitute a risk of shock to persons.

 

 

 
Explanation of symbols used in this manual or on the 
rear/underside of the apparatus:   

 

 

 

 
 
 

 

 

 

TO COMPLETELY DISCONNECT THIS APPARATUS FROM 
THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD 
PLUG FROM THE AC RECEPTACLE. 
THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL 
REMAIN READILY ACCESSIBLE. 
Disconnect supply cord before changing fuse. 
Refer servicing to qualified service personnel. 
 
WARNING:  TO REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR 
MOISTURE AND OBJECTS FILLED WITH LIQUIDS, SUCH AS 
VASES, SHOULD NOT BE PLACED ON THIS APPARATUS

 

Read, keep and follow these instructions. 

 

Heed all warnings. 

 

Do not use the apparatus near water, ie near a bathtub, 
kitchen sink, laundry tub, in a wet basement, near a 
swimming pool etc. 

 

Clean only with dry cloth. 

 

Do not block any ventilation openings. Install in 
accordance with the Manufacturer’s instructions. Site 
the apparatus so that its location or position does not 
interfere with its proper ventilation. For example, the 
apparatus should not be situated on a bed, sofa, rug, or 
similar surface that may block the ventilation openings, 
or placed in a built in installation such as a bookcase or 
cabinet that may impede the flow of air through the 
ventilation openings. 

 

Do not install near any heat sources such as radiators, 
heat registers, stoves, or other apparatus that produce 
heat. 

 

Do not defeat the safety purpose of the polarized or 
grounding type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not fit into your outlet; consult 
an electrician for replacement of the obsolete outlet. 

 

Protect the power cord from being walked on or 
pinched particularly at plugs, convenience receptacles, 
and at the point where they exit from the apparatus. 

 

 

Unplug this apparatus during lightning storms or when 
unused for long periods of time. 

 

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug has been damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus 
has been exposed to rain or moisture, does not operate 
normally, or has been dropped. 

 

Mains plug: Use the mains plug to disconnect the 
apparatus from the mains supply. The mains plug must 
be accessible at all times. Use the mains switch (if 
applicable) when the apparatus is not in use. 

 

Objects and liquid entry: Do not let objects or liquids fall 
into the apparatus. Do not expose the apparatus to 
dripping or splashing. Do not place a vessel containing 
liquid on top of the apparatus. 

 

No naked flame sources, such as lighted candles, 
should be placed on the apparatus. 

 

The apparatus has been designed for use in moderate 
and tropical climates 

 

 

 

This appliance is fitted with a non-rewireable 10 amp mains plug.  The plug contains a 10 amp fuse. If the fuse has blown it can be replaced as 
follows: 
a) Pull out the black fuse cover/carrier. 
b) Remove and dispose of the blown fuse. 
c) Fit a new 10 amp BS1362 approved fuse into the carrier and push the carrier back into the plug. 
Always ensure the fuse cover is fitted. If the fuse cover is missing do not use the plug. Contact your Bel Canto retailer to obtain a replacement 
fuse cover. Fuses are for fire protection and do not protect against electric shock. 
 

WARNING: THIS APPLIANCE MUST BE GROUNDED. 

 

 

 

 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 
• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• 

Consult the dealer or an experienced radio/TV technician for help. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The exclamation point within an equilateral triangle 
is intended to alert the user to the presence of 
important operating and maintenance (servicing)

 

instructions in the literature accompanying the 
product.

   

Содержание e.One Phono

Страница 1: ......

Страница 2: ...onic mechanical photocopying recording or otherwise without the prior written permission of the publisher The content of this manual is furnished for information use only is subject to change without notice and should not be construed as a commitment by Bel Canto Design Limited Bel Canto Design Limited assumes no responsibility or liability for any errors or inaccuracies that may appear in this ma...

Страница 3: ...damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Mains plug Use the mains plug to disconnect the apparatus from the mains supply The mains plug must be accessible at all times Use the mains switch if applicable when the apparatus is not in use Objects and liquid entry Do not le...

Страница 4: ... PHONO User s Guide 1 one Power cord 6 6 2 meters long Carefully unpack each piece and check for shipping damage If there is any damage or if anything is missing please contact your dealer distributor or Bel Canto Design Save all packing materials as they are specially designed to protect the unit during transportation or shipping If the packing becomes lost or damaged please contact your dealer d...

Страница 5: ... the analog input of your DAC Dip Switches for Gain and Resistive Loading Your cartridge manufacturer will recommend a certain load which may require adjusting these settings Refer to the following pages to adjust settings RCA Inputs Connect from your turntable The sonic performance of the PHONO will begin to stabilize after 100 hours of continuous power up We recommend leaving the PHONO powered o...

Страница 6: ...y pressing the Gain Switches to the DOWN position The interim positions can be used to optimize setup for different cartridge and preamplifier sensitivities Ensure that you MUTE your line stage Preampilfier or analog input on your DAC and turn the PHONO OFF before changing this setting to prevent a large transient from damaging your loudspeakers or power amplifiers Input Resistor Load Setting Swit...

Страница 7: ... 50dB MC Low Up Down 58dB MC Down Down 60dB MC High Resistance Adjustment 1000 500 100 50 Effective Load Resistance ohms Up Down Down Down 980 Down Up Down Down 495 Down Down Up Down 100 Down Down Down Up 50 Up Up Down Down 331 Up Down Up Down 91 Down Up Up Down 83 Down Up Down Up 45 Up Up Up Down 77 Down Up Up Up 31 ...

Страница 8: ...01 Maximum Output Level 7 V RMS Output Impedance 100 Ohms Single Ended and Balanced Input Impedance Adjustable See page 6 Gain Level Options Adjustable See Page 6 Power On usage 10W Power Off usage 0 0W Internally Set Operating Voltages 100 120VAC or 230 240VAC 50 60 Hz Dimensions 8 5 W x 12 5 D x 3 H 216 mm x 318 mm x 75 mm Weight 10 lbs 4 5 kg ...

Страница 9: ...0 3 3 1995 A1 2001 A2 2005 EN 60065 2002 A12 2011 Manufacturer Bel Canto Design Ltd 221 1st Street North Minneapolis MN 55401 USA The equipment identified here conforms to the Directive s and Standard s specified above Type of Equipment Audio Preamplifier Models PHONO Date January 2017 Bel Canto Design Ltd 221 1st Street North Minneapolis MN 55401 USA Tel 612 317 4550 Fax 612 359 9358 ...

Страница 10: ...bel canto e One version 2 0 ...

Отзывы: