Beko Room Air Conditioner Скачать руководство пользователя страница 14

Operating Instructions

Delay off timer

Delay on timer

Delay off and on timer

Delay on and off timer

1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically.
2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times. 

The sleep mode is available for 1 to 7 times. 
To alter the time period in steps of 1 hour, press the SLEEP MODE AUTO BUTTON while aiming at air conditioner.

3. • (

In case of non-Inverter Model)

Make sure the sleep mode LED lights up.
To cancel the sleep mode, press the SLEEP MODE AUTO BUTTON several times until the sleep mode LED lights off.

• 

(In case of Inverter Model)

Make sure the Timer LED lights up.
To cancel the sleep mode, press the SLEEP MODE AUTO BUTTON several times until the Timer LED lights off.

• The sleep mode will operate indoor fan at slow speed in cooling mode and at medium speed in heating mode for

pleasant sleep.

In cooling mode or healthy dehumidification mode:

The setting temperature will rise automatically two times by 1°C over next consecutive 30 minutes (2°C in 1 hour) for a
comfortable sleep. Now this will be the final setting temperature as long as sleep mode is functioning.

NOTE

1. Time can be set only when you press the RESET BUTTON. Having replacing the batteries, 

you should press the RESET BUTTON to reset the time. Press the Start/Stop button.

2. Press 2nd F button and check if           icon is on.
3. Press the TIME SETTING BUTTONS until the desired time is set.
4. Press the TIME SET/CANCEL BUTTON.

Check the indicator for A.M. and P.M.

NOTE

1. Make sure to set current time correctly on the display of the remote controller.
2. Press 2nd F button.

3. Press the ON/OFF TIMER BUTTONS to turn timer on or off.

4. Press the TIME SETTING BUTTONS until the desired time is set.

5. To set the selected time, press the TIMER SETTING BUTTONS aiming the remote controller at the 

signal receptor.

To cancel the timer setting

Check if            icon is off.
Press the TIMER CANCEL BUTTON aiming the remote controller at the signal receptor.
(The timer lamp on the air conditioner and the display will go off.)

Select one of the following four types of operation.

NOTE

ON

OFF

CANCEL

SET

CANCEL

SET

CANCEL

SET

Sleep Mode

Setting the Current Time

Timer Setting

14

Room Air Conditioner

Содержание Room Air Conditioner

Страница 1: ...S MANUAL IMPORTANT Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly P No Rev a 2 ...

Страница 2: ... should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 6 6 6 6 7 7 7 7 8 8 8 8 9 10 11 11 12 12 12 13 13 14 14 14 15 15 15 16 16 17 17 17 18 18 B Electrical Safety Temporary Use of an Adapter Temporary Use of an E...

Страница 3: ...ely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an Auth...

Страница 4: ... failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repai...

Страница 5: ... in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the...

Страница 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Страница 7: ...c mode by using a multiple lighting system Timer Lights up during timer operation non Inverter Model Lights up during timer operation or sleep mode auto operation Inverter Model only Defrost mode Power Display Indicates the setting temperature and operation mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outd...

Страница 8: ...ing replace both of the batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case some other appl...

Страница 9: ...he timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON OPTIONAL Used to circulate the room air without cooling or heating ENERGY SAVING COOLING MODE BUTTON OPTIONAL For inverter type models 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 BUTTON OPTIONAL Used to start or stop the purification function 14 HORIZONTAL AIRF...

Страница 10: ...p Model For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON Each ...

Страница 11: ...is automatically set according to the optimization algorithm responding to the current room temperature status so that the room condition is kept healthy and comfortable even in the very humid season Auto Changeover Healthy Dehumidification Auto operation basically is heating or cooling function of the air conditioner But during this operation the controller changes the operation mode automaticall...

Страница 12: ...super high fan speed and 18 C setting temperature for 30 minutes for fast and effective cooling Similarly jet heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes This activion kills and destroys the contaminants completely to provide clean and hygienic air You can activate this operation by pressing ...

Страница 13: ...ication mode Forced operation Operation procedures when the remote control can t be used The operation will be started if the ON OFF button is pressed If you want to stop operation re press the button ON OFF button Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Sett...

Страница 14: ...mes by 1 C over next consecutive 30 minutes 2 C in 1 hour for a comfortable sleep Now this will be the final setting temperature as long as sleep mode is functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the Start Stop button 2 Press 2nd F button and check if icon is on 3 Press the TIME S...

Страница 15: ...make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system NOTE CHAOS Air economizes power consumption and prev...

Страница 16: ...m soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Activion Filters The activion filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filte...

Страница 17: ... will blink in case if thermistor fails Please contact your serviceman dealer in such a situation Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform t...

Страница 18: ...o curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or turn it off while using the air con...

Отзывы: