QWIK-PURE 100
22
Note:
• It is recommended that an original
OEKOSORB cartridge be kept in stock
at all times.
• Only use OEKOSORB cartridge to en-
sure operational reliability. The original
cartridges are identified by their label-
ling (
C
) and the test seal.
• Do not use any other material. Oth-
erwise the correct functioning of the
QWIK-PURE (wastewater quality,
through-put capacity, service life) can-
not be guaranteed.
• Remove plastic bag if present before
cartridge installation!
Procedure
• Step 1. Keep the plastic bag of the
new cartridge for wrapping up the old one.
•
Step 2. Shut off the condensate feed to
the unit.
•
Step 3. Remove the QWIKPURE lid by
loosening the 4 screws on the lid top.
•
Step 4. Lift the old cartridge for the main
tank and allow it to drain. Once the cartridge
has drained place it in the plastic bag and
dispose of the unit according to your local
regulations.
•
Step. 5 Thoroughly clean the main tank
area with non-abrasive and surfactant-free
cleaner.
•
Step. 6 Insert new cartridge slowly and
ensure that the guide pins located on
each side of the cartridge match up to the
container holes
•
Step 7. Re-install the lid with the 4 screws.
Make sure not to over tighten.
•
Step 8. MUST BE COMPLETED before
introducing compressed air condensate to
unit. Pour water into the unit from the top
through the pressure relief chamber area.
•
Step 9. Stop pouring the water (approx. 18
gallons) when it starts to come out at the
water outlet that is located on the side of
the unit.
•
Step 10. Wait approximately 5 mins so the
cartridge will adsorb some of water & add
additional water to the unit until you see
water coming out of the outlet again. Once
this has been accomplished the unit will
be recharged and ready for full operation.
•
Step 11. You know can introduce conden-
sate into unit via the multiple inlet adaptor
located on the top lid.
Maintenance • Mantenimiento
Entretien • Manutenção
OEKOSORB cartridge
OEKOSORB cartucho
OEKOSORB catouche
OEKOSORB cartucho
Weight
Peso
Poids
Peso
Order Ref.
Nº de referencia
No de commande
N° de referência
19.8 lbs
4004442
19,7" 500 mm
english
Содержание QWIK-PURE 100
Страница 26: ...QWIK PURE 100 26 Components Componentes Nomenclature des pièces Componentes ...
Страница 29: ...QWIK PURE 100 29 ...