for any damages that will arise due to using the
product without a grounding installation in accordance
with the local regulations.
DANGER:
The product must be connected to the mains
supply only by an authorised and qualified
person. The product's warranty period starts
only after correct installation.
Manufacturer shall not be held responsible for
damages arising from procedures carried out
by unauthorised persons.
DANGER:
The power cable must not be clamped, bent or
trapped or come into contact with hot parts of
the product.
A damaged power cable must be replaced by
a qualified electrician. Otherwise, there is risk
of electric shock, short circuit or fire!
•
Connection must comply with national
regulations.
•
The mains supply data must correspond to the
data specified on the type label of the product.
Type label is at the rear housing of the product.
•
Power cable of your product must comply with
the values in "Technical specifications" table.
DANGER:
Before starting any work on the electrical
installation, disconnect the product from the
mains supply.
There is the risk of electric shock!
Connecting the power cable
While performing the wiring, you must apply
with the national/local electrical regulations
and must use the appropriate socket
outlet/line and plug for oven. In case of the
product's power limits are out of current
carrying capability of plug and socket
outlet/line, the product must be connected
through fixed electrical installation directly
without using plug and socket outlet/line.
1. If it is not possible to disconnect all poles in the
supply power, a disconnection unit with at least 3
mm contact clearance (fuses, line safety switches,
contactors) must be connected and all the poles
of this disconnection unit must be adjacent to (not
above) the product in accordance with IEE
directives. Failure to obey this instruction may
cause operational problems and invalidate the
product warranty.
Additional protection by a residual current circuit
breaker is recommended.
If a cable is supplied with the product:
2.
For single-phase connection,
connect the wires
as identified below:
•
Brown/Black cable = L (Phase)
•
Blue/Grey cable = N (Neutral)
•
Green/yellow cable = (E)
(Ground)
»
or
•
Grey/Black cable = L (Phase)
•
Blue/Brown cable = N (Neutral)
•
Green/yellow cable = (E)
(Ground)
Installing the product
If the oven is below:
A
min.15 mm
B
min. 5 mm
C
20 mm
If the board is below:
It is required to leave a ventilation opening at the rear
section of the furniture as illustrated in the following
figure.
*