Mobile type air conditioners (local air conditioners) / User Manual
13 / 28 EN
C
Note:
The control is capable of displaying temperature in degrees Fahrenheit or
degrees Celsius. To convert from one to the other, press and hold the Up and Down
buttons at the same time, for 3 seconds.
5. MODE select button
Selects the appropriate operating mode. Each time you press the button, a mode is selected in a
sequence that goes from AUTO, COOL, DRY, FAN and HEAT (cooling only models without). The
mode indicator light illuminates under the different mode settings.
6. TIMER button
Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the
+ & - buttons. The timer on/off indicator light illuminates under the timer on/off settings.
7. SWING button
(Applicable to the models with auto swing feature only)
Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can
stop the louver at the desired angle.
8. LED display
Shows the set temperature in "°C" or ("°F" no display) and the Auto-timer settings.
While on DRY and FAN modes, it shows the room temperature.
Error codes and protection code:
E1-
Room temperature sensor error-Unplug the unit and plug it back in. If error repeats, call for
service.
E2-
Evaporator temperature sensor error-Unplug the unit and plug it back in. If error repeats, call for
service.
E3-
Condenser temperature sensor error-Unplug the unit and plug it back in. If error repeats, call for
service (on some models).
E4-
Display panel communication error-Unplug the unit and plug it back in. If error repeats, call for
service.
P1-
Bottom tray is full - Connect the drain hose and drain the collected water away. If protection
repeats, call for service.
9. Power management feature
When the ambient temperature is lower (Cooling mode) or higher (Heating mode) than the setting
temperature for a period of time, the unit will be automatically operate power management
feature. The compressor and fan motor stop and the power management indicator light
illuminates. When the ambient temperature is higher (Cooling mode) or lower (Heating mode) than
the setting temperature, the unit will be automatically quit the power management feature. The
power management indicator light turns dark and the compressor and (or) fan motor run.
5
Air conditioner features
Содержание BEPN 09C
Страница 27: ......
Страница 28: ...www beko com ...
Страница 29: ...Mobilni tip klima uređaja lokalni klima uređaji Korisnički priručnik BEPN 09C BEPN 09H BEPN 12C BEPN 12H SR ...
Страница 55: ......
Страница 56: ...www beko com ...