Inspection and maintenance
16
BEKOMAT® 31U IF built-in F
Note:
It is imperative to observe all hazard statements and warnings listed here.
Please also observe all regulations and notes regarding industrial safety and fire prevention
at the place of installation.
As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components.
Therefore, skin contact should be avoided.
Condensate is subject to mandatory waste disposal. As such, it must be collected in suitable containers,
and disposed of or processed properly.
Maintenance recommendation:
Replace the service unit (5)
after 8,000 operating hours or max. one year:
1.
Remove the control unit (1)
by pressing the arresting hook (2).
2.
Unfasten the BEKOMAT
®
31U IF from the outlet
(3).
3.
Remove the design shell (4) (if there is one)
using a screwdriver (10).
4.
Detach the service unit (5) from the tubing
at the inlet by removing the union nut.
5.
or
remove the screws (6) from the angle nozzle
(7).
6.
Check whether or not the new service unit (5)
goes with the control unit (1)
(model designation and colour of the arresting
hook (2)).
7.
Installation of the new service unit (5)
in reverse order.