![Beko BEKOMAT 12i Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/beko/bekomat-12i/bekomat-12i_original-installation-and-operation-manual_21875041.webp)
7.2.1 Single device connection
Connection work - single device
Illustration
Description / explanation
1
2
1. Loosen the 4 screws
[2]
.
2. Lift the top cover
[1]
.
B
1
36
4
5
6
7
3. Raise the top cover
[1]
slightly and pull the terminal
clamp
[36]
off.
4. Remove the plug
[7]
and screw the cable gland
components
[4, 5, 6]
off the right cable gland
[B]
.
6 mm
50 mm
(1.97 in)
(0.23 in)
5. Prepare the connection cable
[X6]
.
4
X6
B
5
6
6. Fit the cable gland components
[4, 5, 6]
over the
connection cable
[X6]
.
7. Insert the connection cable
[X6]
into the
right cable gland
[B]
.
Original installation and operation manual